2004
DOI: 10.15253/2175-6783.2004000200006
|View full text |Cite
|
Sign up to set email alerts
|

Manguitos de largura correta – levantamento em um grupo específico de crianças e adolescentes

Abstract: Objetivou-se investigar a largura de manguitos mais adequada para a medida da pressão arterial de crianças e adolescentes levando em conta a relação recomendada de 40% da circunferência do braço. O estudo foi realizado em Fortaleza-CE e incluiu 166 crianças e adolescentes de ambos os sexos entre 6 e 18 anos de idade. A maioria (53%) era do sexo feminino. A circunferência dos braços dos indivíduos variou de 14 cm a 49 cm. Os tamanhos de manguitos mais adequados foram os de 8, 9 e 10 cm, com predominância do de … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 4 publications
(8 reference statements)
0
1
0
Order By: Relevance
“…18 Therefore, narrow cuffs yield elevated BP values, leading to an increase in the consumption of antihypertensive drugs, while larger cuffs used on lean patients result in incorrect diagnosis and treatment of systemic arterial hypertension. 17,19 Moreover, 78.3% (61/78) of sphygmomanometer/cuff sets corresponded between brands. Of the 17 devices that showed a mismatch between the set, 11 belonged to the hospital, where there were no indications that the combination used was INMETRO approved.…”
Section: Discussionmentioning
confidence: 93%
“…18 Therefore, narrow cuffs yield elevated BP values, leading to an increase in the consumption of antihypertensive drugs, while larger cuffs used on lean patients result in incorrect diagnosis and treatment of systemic arterial hypertension. 17,19 Moreover, 78.3% (61/78) of sphygmomanometer/cuff sets corresponded between brands. Of the 17 devices that showed a mismatch between the set, 11 belonged to the hospital, where there were no indications that the combination used was INMETRO approved.…”
Section: Discussionmentioning
confidence: 93%
“…Desde a década de 80 até os dias atuais a recomendação usada é de 80%, estabelecendo uma relação entre comprimento e largura de 2 para 1 (12) . Por conta disso e para evitar esse tipo de erro, é prudente usar manguitos adequados à CB (15)(16)(17) . Aparelhos mal conservados ou com vazamentos podem não ocluir o fluxo arterial corretamente e assim não realizarem a medida fiel da PA.…”
Section: Anexo 1_unclassified