2022
DOI: 10.1016/j.pacs.2022.100347
|View full text |Cite
|
Sign up to set email alerts
|

Manganous-manganic oxide nanoparticle as an activatable microwave-induced thermoacoustic probe for deep-located tumor specific imaging in vivo

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 44 publications
(47 reference statements)
0
7
0
Order By: Relevance
“…The thermoacoustic imaging in vivo was according to the previous report. 62 Briefly, 1.2 GHz microwave generator was adjusted to transmit 0.5 μs microwave pulse with 10 Hz of repetition frequency and 250 kW of peak power. The microwave pumped through the waveguide with an effective radiation area 8.3 × 16.5 cm 2 .…”
Section: ■ Experimental Methodsmentioning
confidence: 99%
“…The thermoacoustic imaging in vivo was according to the previous report. 62 Briefly, 1.2 GHz microwave generator was adjusted to transmit 0.5 μs microwave pulse with 10 Hz of repetition frequency and 250 kW of peak power. The microwave pumped through the waveguide with an effective radiation area 8.3 × 16.5 cm 2 .…”
Section: ■ Experimental Methodsmentioning
confidence: 99%
“…Similarly, Sun et al [56] constructed a TME-responsive nanoplatform assembled by chlorine e6 (Ce6) modified carbon dots and Cu 2+ ions (named Cu/CC NPs). The Cu/CC NPs showed quenched fluorescence in the aggregation state by Cu 2+ MnO x -HMSN pH Dynamic T 1 -weighted MRI 2012 [ 33] DOX-mMnO 2 @ C1498 AML cell membrane pH and GSH Dynamic T 1 -weighted MRI 2023 [ 34] BSA/Mn-LDH pH Dynamic T 1 -weighted MRI 2017 [ 35] Iron oxide nano-grenade pH Dynamic T 1 -weighted MRI 2014 [ 38] PEG-USPIONs@CaCO 3 nanoprobe pH T 2 -T 1 Switchable MRI 2021 [ 39] Janus nanocomposite consisting of a MOF and UCNP H 2 O 2 and GSH Dynamic T 2 -weighted MRI 2021 [ 40] Cobalt Complexes (Co-TPA) Oxygen Dynamic T 1 and T 2 -weighted MRI 2016 [ 41] GGT activatable chemiluminescent probe GGT Dynamic Chemiluminescence imaging 2019 [ 44] AIE fluorophore (TPEQH) with a phosphate group ALP Dynamic FLI 2020 [ 49] Liposome-based probe pH Dynamic FLI 2020 [ 50] Afterglow luminescent AIE NP AST Dynamic afterglow luminescence imaging 2019 [ 51] Ag 2 S-QD Vesicles pH NIR-II FLI 2021 [ 55] Cu/CC NPs pH and GSH Dynamic FLI 2020 [ 56] Mn 3 O 4 -PEG-RGD NP pH and GSH Dynamic MTAI 2022 [ 57] Pd-Pep-BSA-CQ4T-Ag nano-system pH and H 2 O 2 Dynamic FLI and PAI 2022 [ 58] ions. This fluorescence signal recovered efficiently once Cu/CC NPs disassemble under the stimulation of TME.…”
Section: Tme-responsive Fli Contrast Agentsmentioning
confidence: 99%
“…In addition to the above-mentioned TME-responsive MRI and FLI contrast agents, other nanomaterials with signals changed by the TME can also monitor tumor accumulation. For example, Zhang et al [57] developed GSH and pH-responsive microwaveinduced thermoacoustic imaging (MTAI) contrast agents by using Mn 3 O 4 -PEG-RGD NPs (Figure 6a,b). These NPs released manganese ions and increased conductivity under acidic and high GSH environments, resulting in enhanced thermoacoustic signals by altering the thermo-acoustic conversion efficiency and microwave loss capacity.…”
Section: Other Tme-responsive Contrast Agentsmentioning
confidence: 99%
See 2 more Smart Citations