2020
DOI: 10.1016/j.ijbiomac.2019.12.197
|View full text |Cite
|
Sign up to set email alerts
|

Maltodextrin for corrosion mitigation of zinc in sulfamic acid: Electrochemical, surface and spectroscopic studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 58 publications
0
10
0
Order By: Relevance
“…This suggests that Curam drug adsorbs at metal/ electrolyte interfaces and act as an interface type of inhibitor. 36 EIS parameters in Table 5, are obtained by fitting using the corresponding equivalent circuit diagram as shown in Figure 5b, where R s and R ct represent the solution resistance between the metal electrode and the reference electrode and the chargetransfer resistance corresponding with the corrosion reaction at the metal /solution interface, respectively. The double layer capacitance (C dl ) is placed in parallel to the charge transfer resistance (R ct ) due to the charge transfer reaction.…”
Section: Eis Measurementsmentioning
confidence: 99%
“…This suggests that Curam drug adsorbs at metal/ electrolyte interfaces and act as an interface type of inhibitor. 36 EIS parameters in Table 5, are obtained by fitting using the corresponding equivalent circuit diagram as shown in Figure 5b, where R s and R ct represent the solution resistance between the metal electrode and the reference electrode and the chargetransfer resistance corresponding with the corrosion reaction at the metal /solution interface, respectively. The double layer capacitance (C dl ) is placed in parallel to the charge transfer resistance (R ct ) due to the charge transfer reaction.…”
Section: Eis Measurementsmentioning
confidence: 99%
“…The values such as average surface roughness (R a ), root mean square roughness (R q ), and R max values derived from AFM studies are provided in Table 6. It is clear from the results of R a , R q, and (P-V) that for the inhibited sample, the values are much lower than in the absence of pectin (Pais and Rao 2020). This is a clear indication of the adsorbed pectin on the surface of the EN8 steel.…”
Section: Atomic Force Microscopy (Afm) Analysismentioning
confidence: 83%
“…The values of maximum roughness R max were 197 nm for polished, 5025 nm for corroded, and 1990 nm for the inhibited surface. This is a clear indication of the adsorbed pectin on the surface of the AISI1040 steel (Pais & Rao, 2020), due to a decrease in the R max value for the inhibited sample surface when compared with the corroded sample roughness value.…”
Section: Sem and Afm Analysismentioning
confidence: 93%