Magnitude of misfit threshold in implant-supported restorations: A systematic review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0
1

Year Published

2024
2024
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 33 publications
0
7
0
1
Order By: Relevance
“…A recent systematic review has shown that 160 μm of vertical and 150 μm of horizontal misfit did not cause complications in implant-supported restorations. 8 Inter-implant distance deviation threshold of 100 μm and angular deviation threshold of 0.4 while digitizing 2 adjacent implants have been reported. 7 When the results of the present study were interpreted based on these reported values, it can be hypothesized that FPDs fabricated with tested scans may have clinically acceptable fit, particularly for Model 1.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…A recent systematic review has shown that 160 μm of vertical and 150 μm of horizontal misfit did not cause complications in implant-supported restorations. 8 Inter-implant distance deviation threshold of 100 μm and angular deviation threshold of 0.4 while digitizing 2 adjacent implants have been reported. 7 When the results of the present study were interpreted based on these reported values, it can be hypothesized that FPDs fabricated with tested scans may have clinically acceptable fit, particularly for Model 1.…”
Section: Discussionmentioning
confidence: 99%
“…Maximum mean 3D distance deviation reported in those studies was 178 μm, 11 which is higher than both maximum median 3D (172.17 μm in Model 3) and inter‐implant (24.92 μm in Model 2) distance deviations measured in the present study. A recent systematic review has shown that 160 μm of vertical and 150 μm of horizontal misfit did not cause complications in implant‐supported restorations 8 . Inter‐implant distance deviation threshold of 100 μm and angular deviation threshold of 0.4° while digitizing 2 adjacent implants have been reported 7 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In socket-screwdriver constructs, interfacial misfit is an inherent consequence of manufacturing tolerances and design parameters [20,32]. The misfit refers to the variation or mismatch between the socket and screwdriver components, which can affect the performance and stability of the implant.…”
Section: Discussionmentioning