2011
DOI: 10.1103/physrevb.84.165319
|View full text |Cite
|
Sign up to set email alerts
|

Magnetophotoluminescence study of intershell exchange interaction in CdTe/ZnTe quantum dots

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

7
53
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 40 publications
(60 citation statements)
references
References 32 publications
7
53
0
Order By: Relevance
“…28 However, in accordance with Ref. 25 and 27 we find that for telluride QDs the distances between the emission lines vary almost proportionally to each other ( Fig. 1(c)).…”
Section: Resultssupporting
confidence: 90%
“…28 However, in accordance with Ref. 25 and 27 we find that for telluride QDs the distances between the emission lines vary almost proportionally to each other ( Fig. 1(c)).…”
Section: Resultssupporting
confidence: 90%
“…Such an emission is not observed in PL measurements performed in a typical experimental setup with optical axis parallel to the QD growth axis 10,18,19 . However, the dark exciton PL can be revealed by using an in-plane setup geometry (i.e., the optical axis perpendicular to the growth axis).…”
mentioning
confidence: 86%
“…Under strong excitation power (short dot repopulation time) the bright exciton PL dominates the spectrum, as X b lifetime is usually much shorter compared to the dark exciton one. However, in the low excitation power regime (i.e., when the dot repopulation time is long enough to allow undisturbed recombination of the X d ), the dark exciton emission line is clearly visible (its identification is based on the spectral position, which matches relative energy of the dark exciton determined in the magnetophotoluminescence experiments 18 ). This result indicates the presence of radiative recombination channel of the dark exciton confined inside a QD.…”
mentioning
confidence: 99%
“…We identified strong lines related to neutral exciton in the highest energy, trions in intermediate energies, biexction in lowest energy, and weaker lines associated with higher charged states 9,18,19 . Emission lines were identified by a combination of various methods: measurement of luminescence intensity as a function of excitation power, linear polarization anisotropy measurements (Fig.…”
Section: New Opportunities Coming From Low-density Of Dotsmentioning
confidence: 99%
“…6) and study of properties 17,18 almost all emission lines in broad µPL spectrum. This is unavailable without using additional treatments like mesas in usual samples.…”
Section: New Opportunities Coming From Low-density Of Dotsmentioning
confidence: 99%