2021
DOI: 10.1109/tim.2021.3120375
|View full text |Cite
|
Sign up to set email alerts
|

Magnetocardiography Measurements by Microfabricated Atomic Magnetometer With a 3-D Spherical Alkali Vapor Cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 41 publications
0
7
0
Order By: Relevance
“…Although we saw in section 3 that reducing the number of atoms worsens the sensitivity of a magnetometer, there may be strong motivations for miniaturization-including reduced standoff distance and improved spatial resolution, or integration of the cell into small quantum systems [23,96,111,[113][114][115][149][150][151] with low size, weight, and power (SWaP). Production of MEMS ('micro-electromechanical systems') vapor cells for magnetometers and atomic clocks is a rapidly growing field, typically incorporating anodic-bonding techniques [152][153][154].…”
Section: Need a Microfabricated Vapor Cell-what Are My Options?mentioning
confidence: 99%
“…Although we saw in section 3 that reducing the number of atoms worsens the sensitivity of a magnetometer, there may be strong motivations for miniaturization-including reduced standoff distance and improved spatial resolution, or integration of the cell into small quantum systems [23,96,111,[113][114][115][149][150][151] with low size, weight, and power (SWaP). Production of MEMS ('micro-electromechanical systems') vapor cells for magnetometers and atomic clocks is a rapidly growing field, typically incorporating anodic-bonding techniques [152][153][154].…”
Section: Need a Microfabricated Vapor Cell-what Are My Options?mentioning
confidence: 99%
“…For example, Fig. 3 (original figures available in [86] [87]) shows the typical size of an OPM and SURF. Most of AMs are just couple centimeters in their largest dimension [75] [37] [67] [34].…”
Section: B Atomic Magnetometers (Am)mentioning
confidence: 99%
“…In 2021, Jin Zhang et al designed the SERF atomic magnetometer with a spherical gas chamber for cardio magnetography measurements. Under magnetically shielded conditions, the magnetometer sensitivity reached 125 at 15 Hz and was able to obtain morphologically clear cardio magnetic signals [ 133 ]. The main competitor of VCSELs in the application of bio-sensing is the DFB laser, which has the advantages of high power, narrow line-width, low noise, and high stability.…”
Section: Atomic Magnetometer In the Medical Fieldmentioning
confidence: 99%