2013
DOI: 10.1016/j.ijcard.2013.07.215
|View full text |Cite
|
Sign up to set email alerts
|

Magnetocardiographic demonstration of complex ventricular preexcitation resulting in ablation failure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…Indeed, although experience is still limited to only few institution, contactless MCG is one of the most promising technology for non‐invasive cardiac electro‐anatomical imaging and accurate localization of arrhythmogenic substrates (Brisinda, Venuti, Sorbo, & Fenici, ; Fenici & Brisinda, ; Fenici, Brisinda, Venuti, & Sorbo, ; Kwong, Leithäuser, Park, & Yu, ). Several studies, all carried out in magnetically shielded rooms, have demonstrated the usefulness of MCG to study AF (Jurkko et al, , ; Kim & Ahn, ; Kim, Kim, Lee, & Ahn, ; Koskinen et al, ; Lehto et al, ; Lim et al, ; Mäntynen et al, ; Nakai et al, ; Sato et al, ; Yamada & Yamaguchi, ; Yamada, Tsukada, Miyashita, Kuga, & Yamaguchi, ; Yoshida et al, ).…”
Section: Discussionmentioning
confidence: 99%
“…Indeed, although experience is still limited to only few institution, contactless MCG is one of the most promising technology for non‐invasive cardiac electro‐anatomical imaging and accurate localization of arrhythmogenic substrates (Brisinda, Venuti, Sorbo, & Fenici, ; Fenici & Brisinda, ; Fenici, Brisinda, Venuti, & Sorbo, ; Kwong, Leithäuser, Park, & Yu, ). Several studies, all carried out in magnetically shielded rooms, have demonstrated the usefulness of MCG to study AF (Jurkko et al, , ; Kim & Ahn, ; Kim, Kim, Lee, & Ahn, ; Koskinen et al, ; Lehto et al, ; Lim et al, ; Mäntynen et al, ; Nakai et al, ; Sato et al, ; Yamada & Yamaguchi, ; Yamada, Tsukada, Miyashita, Kuga, & Yamaguchi, ; Yoshida et al, ).…”
Section: Discussionmentioning
confidence: 99%
“…Interesting data were also obtained in patients with non-ischemic arrhythmogenic cardiomyopathy ( 96 , 138 , 218 , 219 ), confirmed also by more recent multichannel MCG studies in MSRs ( 220 , 221 ). Further experimental ( 222 ) and clinical research has confirmed the reliability of unshielded MCG mapping as a unique method for the contactless ambulatory study of myocardial ischemia, for fetal MCG ( 223 , 224 ), for risk assessment, and for follow-up of asymptomatic Brugada patients ( 225 ) to identify patients with complex ventricular preexcitation ( 226 ).…”
Section: Unshielded Mcg: the Pastmentioning
confidence: 94%
“…While clinical studies, which was carried out in specialized centers with shielded and unshielded SQUID-based MCG systems, enhanced the evidence for MCG 3D electroanatomical localization accuracy and for risk assessment of arrhythmogenic mechanisms/substrates ( 82 , 83 , 90 , 226 , 245 251 ), a renewed interest for biomagnetic sensor technology has raised again not only at the academic but also at the industrial level ( 252 , 253 ). In fact, apart from the traditionally available multichannel cryogenic MCG systems working in MSRs ( 246 , 254 – 259 ) and a more downscaled price for sequential unshielded MCG mapping ( 77 , 256 259 ), three younger companies have manufactured innovative multichannel MCG devices, based on different sensor technologies, all of them specifically designed for clinical application at minimized running costs and with optimized operational simplicity.…”
Section: Unshielded Mcg: the Presentmentioning
confidence: 99%