2016
DOI: 10.1007/s10439-016-1784-2
|View full text |Cite
|
Sign up to set email alerts
|

Magnetically Controlled Endourethral Artificial Urinary Sphincter

Abstract: Urinary incontinence is a largely spread disfunction that affects more than 300 million people worldwide. At present, no technological solutions are able to restore continence in a minimally invasive and effective way. In this article the authors report the design, fabrication, and testing of a novel artificial endourethral urinary sphincter able to fully restore continence. The device can be inserted/retracted in a minimally invasive fashion without hospital admission, does not alter the body scheme and can b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
20
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 32 publications
0
20
0
Order By: Relevance
“…(d) Vysera Biomedical Limited's patent . (e) Mazzocchi et al's research prototype . [Color figure can be viewed at http://wileyonlinelibrary.com]…”
Section: Artificial Urinary Sphinctersmentioning
confidence: 99%
See 2 more Smart Citations
“…(d) Vysera Biomedical Limited's patent . (e) Mazzocchi et al's research prototype . [Color figure can be viewed at http://wileyonlinelibrary.com]…”
Section: Artificial Urinary Sphinctersmentioning
confidence: 99%
“…In 2017, Mazzocchi et al designed a novel unisex endo‐urethral AUS, which could be inserted into the urethra with endo‐luminal access and with a quick procedure (Fig. e) . It was tested ex vivo on a human cadaver with successful results.…”
Section: Artificial Urinary Sphinctersmentioning
confidence: 99%
See 1 more Smart Citation
“…Encrustations and infections, indeed, still represent an open issue for medical devices to be employed in the urinary system: Urine alters the device properties and functionality, raising the need for frequent replacements 11 . Regarding the AUS reported in Reference 10, the main component subjected to a risk of functional failure due to encrustations is the polymeric valve, made of polydimethylsiloxane (PDMS) 12 . Anyhow, there are many other endo‐urethral devices based on silicone 9 .…”
Section: Introductionmentioning
confidence: 99%
“…9 Recently, the authors proposed an innovative endo-urethral AUS based on a unidirectional polymeric valve and a magnetic activation/deactivation system. 10 Such a device can be inserted/ removed in a minimally invasive fashion such that it does not alter the body scheme and can be applied to both women and men.…”
mentioning
confidence: 99%