2020
DOI: 10.1016/j.chemosphere.2019.124621
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic solid phase extraction of bisphenol A, phenol and hydroquinone from water samples by magnetic and thermo dual-responsive core-shell nanomaterial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 47 publications
(17 citation statements)
references
References 23 publications
0
17
0
Order By: Relevance
“…In order to compare the proposed method with other existing techniques for determination of BPA, a literature survey was done, the results of which are shown in Table 2 [17,22,28–35]. The results indicated that the introduced FIT‐SPME with HPLC–UV has an acceptable analytical parameter for BPA determination.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to compare the proposed method with other existing techniques for determination of BPA, a literature survey was done, the results of which are shown in Table 2 [17,22,28–35]. The results indicated that the introduced FIT‐SPME with HPLC–UV has an acceptable analytical parameter for BPA determination.…”
Section: Resultsmentioning
confidence: 99%
“…RSD% of 6.3% (n = 3) and 7.9% (n = 3) for the intraday and interday experiments were obtained, respectively, confirming the acceptable precision of the extractive phase. In order to compare the proposed method with other existing techniques for determination of BPA, a literature survey was done, the results of which are shown in Table 2 [17,22,[28][29][30][31][32][33][34][35]. The results indicated that the introduced FIT-SPME with HPLC-UV has an acceptable analytical parameter for BPA determination.…”
Section: Methods Validationmentioning
confidence: 99%
“…An alternative nanomaterial called magnetic and thermo dual‐responsive core‐shell nanomaterial (Fe@SiO2@poly(N‐isopropylacrymide‐co‐methacrylic acid, Fe@SiO2@PNIPAM‐co‐MAA) was developed. This smart strategy integrates the magnetism of nanoscale zero valent iron material (well‐known and essential for MSPE) and thermo‐response of the copolymers, resulting in a good enrichment ability for three target phenols [99]. In this work, the material developed has an excellent adsorptive capacity at 25°C (where extraction is performed) but loses its ability with the increase in temperature (>35°C) due to the responsiveness of the polymer.…”
Section: Other Materialsmentioning
confidence: 99%
“…Generally, pH value of the samples is kept lower than the pKa values of analytes in order to keep the analytes in their molecular state. In this way, the solubility of analytes in water decreases, while their interaction with the adsorbent surface increases [19]. The pH value of the aqueous solutions containing fungicides varied from 3 to 11 and the MSPE method was applied to these solutions.…”
Section: Optimization Of Mspe Parametersmentioning
confidence: 99%