Magnetic resonance cisternography for visualization of intracisternal fine structures

Abstract: Magnetic resonance cisternography appears to show great promise for evaluation of patients with neurovascular compression or tumors in and around the basal cisterns; the procedure adds only a small amount of imaging time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
1

Year Published

1999
1999
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(21 citation statements)
references
References 6 publications
0
19
1
Order By: Relevance
“…Although this study was prospective, the authors did not indicate whether the radiologists were blinded to diagnosis before evaluation of the images. Mamata et al [10] also studied MRI in controls, patients with essential hypertension, and patients with secondary hypertension. Patients with essential hypertension had a much higher incidence of vascularinduced brainstem compression.…”
Section: Historical and Anatomic Perspectivementioning
confidence: 96%
“…Although this study was prospective, the authors did not indicate whether the radiologists were blinded to diagnosis before evaluation of the images. Mamata et al [10] also studied MRI in controls, patients with essential hypertension, and patients with secondary hypertension. Patients with essential hypertension had a much higher incidence of vascularinduced brainstem compression.…”
Section: Historical and Anatomic Perspectivementioning
confidence: 96%
“…10) This MR sequence has been utilized in the treatment of cochlear disease, 7) cerebellopontine angle tumor, 11) microvascular decompression, 12) or vertebrobasilar diseases. 8) We employed serial coronal sections of heavily T2-weighted images for depicting occluded arteries.…”
Section: Discussionmentioning
confidence: 99%
“…The time required for 13 images in one direction was 3 minutes and 48 seconds [7]. Pulse gating system, which increased imaging time, was used to reduce CSF related artifacts [7]. In this sequence, CSF was low-signaled and other structures were shown in higher intensity of various degrees including vascular components.…”
Section: Mr Apparatusmentioning
confidence: 99%
“…Sequence parameters used were TR 5800 msec and TE 220 msec, 200 mm field of view, slice thickness of 3 mm and interslice gap of 0.5 mm, 284 Â 512 pixel matrix, echo train length of 23, and 4 excitations. The time required for 13 images in one direction was 3 minutes and 48 seconds [7]. Pulse gating system, which increased imaging time, was used to reduce CSF related artifacts [7].…”
Section: Mr Apparatusmentioning
confidence: 99%