2007
DOI: 10.1007/s00330-007-0714-y
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic resonance angiographic assessment of upper extremity vessels prior to vascular access surgery: feasibility and accuracy

Abstract: A contrast-enhanced magnetic resonance angiography (CE-MRA) protocol for selective imaging of the entire upper extremity arterial and venous tree in a single exam has been developed. Twenty-five end-stage renal disease (ESRD) patients underwent CE-MRA and duplex ultrasonography (DUS) of the upper extremity prior to hemodialysis vascular access creation. Accuracy of CE-MRA arterial and venous diameter measurements were compared with DUS and intraoperative (IO) diameter measurements, the standard of reference. U… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 50 publications
(68 reference statements)
0
9
0
Order By: Relevance
“…Nonetheless, we believe that NCE-MRA images can be used for accurate appraisal of vascular diameters due to the high spatial resolution, bearing in mind our prior study which found lower spatial resolution CE-MRA diameter assessment to correspond reasonably well with DUS assessment and intra-operative measurements. 28 Second, acquisition of distal, proximal and central stations required repositioning of the patient using multiple surface coils. Future work should be aimed at the 'real world' value of an NCE-acquisition of the complete upper extremity, preferably within a single acquisition using large coverage coils in combination with continuously moving table techniques.…”
Section: Discussionmentioning
confidence: 99%
“…Nonetheless, we believe that NCE-MRA images can be used for accurate appraisal of vascular diameters due to the high spatial resolution, bearing in mind our prior study which found lower spatial resolution CE-MRA diameter assessment to correspond reasonably well with DUS assessment and intra-operative measurements. 28 Second, acquisition of distal, proximal and central stations required repositioning of the patient using multiple surface coils. Future work should be aimed at the 'real world' value of an NCE-acquisition of the complete upper extremity, preferably within a single acquisition using large coverage coils in combination with continuously moving table techniques.…”
Section: Discussionmentioning
confidence: 99%
“…113 CE-MRA enables accurate pre-operative detection of upper extremity arterial and venous stenosis and occlusions. 114,115 However, contrast enhanced magnetic resonance angiography (CE-MRA) is not recommended, since use of gadolinium is associated with the potential risk of a nephrogenic systemic fibrosis, especially in patients with severely impaired renal function. 116,117 Promising preliminary results for the pre-operative visualisation of arterial and venous vascular structures with non-contrast enhanced MRA (NCE-MRA) are available.…”
Section: Pre-operative Assessmentmentioning
confidence: 99%
“… 53 CE-MRA can identify the lumen of upper extremity vessels and be more accurate in diameter determination in comparison with DUS. 65 …”
Section: Mrimentioning
confidence: 99%