2022
DOI: 10.1002/mrm.29432
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic resonance and diffusion tensor imaging of the adolescent rabbit growth plate of the knee

Abstract: To assess the ability of MRI-DTI to evaluate growth plate morphology and activity compared with that of histomorphometry and micro-CT in rabbits. Methods:The hind limbs of female rabbits aged 16, 20, and 24 wk (n = 4 per age group) were studied using a 9.4T MRI scanner with a multi-gradient echo 3D sequence and DTI in 14 directions (b-value = 984 s/mm 2 ). After MRI, the right and left hind limb were processed for histological analysis and micro-CT, respectively. The Wilcoxon signed-rank test was used to evalu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 37 publications
(91 reference statements)
0
6
0
Order By: Relevance
“…MD, a measure of cartilage matrix integrity, has been less useful than tractography parameters. In rabbits, DTI tractography correlates with the columnar architecture of the physis and metaphysis seen by histology and micro‐CT 23,24 …”
Section: Musculoskeletal Applications Of Quantitative Diffusionmentioning
confidence: 99%
See 3 more Smart Citations
“…MD, a measure of cartilage matrix integrity, has been less useful than tractography parameters. In rabbits, DTI tractography correlates with the columnar architecture of the physis and metaphysis seen by histology and micro‐CT 23,24 …”
Section: Musculoskeletal Applications Of Quantitative Diffusionmentioning
confidence: 99%
“…Most physeal DTI has been performed at 3 T. Although the imaging parameters have varied, most studies have used 14 to 20 directions, a b ‐value of 600 s/mm 2 , and a tractography reconstruction including an angular threshold of 40° with a FA value of 0.15 15,18–23 . Increasing the angular resolution (greater number of directions) and the b ‐value leads to larger tracts, but this requires larger scan times to maintain the SNR.…”
Section: Musculoskeletal Applications Of Quantitative Diffusionmentioning
confidence: 99%
See 2 more Smart Citations
“…The use of DTI in the physeal–metaphyseal complex for prediction of pediatric growth has been studied for approximately 10 years [ 7 ]. Characterization of columns of cartilage and newly formed bone in the physis and adjacent metaphysis through tractography has proven useful for the determination of height gain and the evaluation of growth failure in pediatric subjects [ 7 , 8 , 9 , 10 , 11 , 12 , 13 ]. Tractography is the result of tensor estimation inside each voxel; the tensor depicts the main direction of unrestricted water diffusion inside the columns running perpendicular to the growth plate [ 2 , 7 ].…”
Section: Introductionmentioning
confidence: 99%