Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2014
DOI: 10.1080/10448632.2014.870442
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic ordering: Neutron diffraction and depolarization studies at Dhruva Reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Temperature variation of neutron powder diffraction measurement from 3 K to 300 K was done in a Cryogenics cryogenfree magnet system, by loading the samples in a vanadium can of height 35 mm and diameter 6 mm. ND measurements on LSMO-0.5 bulk sample were performed at the PD-2 diffractometer, Dhruva reactor, Mumbai, India, at a wavelength of 1.244 Å and in the temperature range of 6-300 K [51][52][53]. The ND data were processed with help of the Rietveld refinement program of FullProf Suite software [48,49].…”
Section: Methodsmentioning
confidence: 99%
“…Temperature variation of neutron powder diffraction measurement from 3 K to 300 K was done in a Cryogenics cryogenfree magnet system, by loading the samples in a vanadium can of height 35 mm and diameter 6 mm. ND measurements on LSMO-0.5 bulk sample were performed at the PD-2 diffractometer, Dhruva reactor, Mumbai, India, at a wavelength of 1.244 Å and in the temperature range of 6-300 K [51][52][53]. The ND data were processed with help of the Rietveld refinement program of FullProf Suite software [48,49].…”
Section: Methodsmentioning
confidence: 99%
“…The structural parameters for this sample at 5 K are listed in table 2. We carried out neutron depolarization experiments [13][14][15][16][17][18] to see if there was a cluster spin glass like ordering in this sample figure 8. But as is clear from these measurements there was no such ordering.…”
Section: Neutron Diffractionmentioning
confidence: 99%
“…The possibility of Raman shift due to free electron-phonon coupling can also be ruled out as the material under study is an insulator over the above mentioned temperature range. Due to the increase in anharmonicity, the phonon frequency and width of a Raman band vary with temperature by following the relations [18] ( )…”
Section: Spin-phonon Coupling From Raman Scattering Measurementsmentioning
confidence: 99%