2017
DOI: 10.1051/e3sconf/20172002002
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic observations at Geophysical Observatory Paratunka IKIR FEB RAS: tasks, possibilities and future prospects

Abstract: Abstract. Continuous magnetic measurements at Geophysical Observatory "Paratunka" (PET) of IKIR FEB RAS are performed since 1967. In the new millennium analogue magnetometers were modernized to digital, the technologies of absolute observations were changed, the data processing was completely transferred to computers, and the status of INTERMAGNET observatory was obtained. Currently, the observatory uses the following magnetometers: (a) for absolute observations -DIflux LEMI-203 (theodolite 3T2KP) and Mag-01 (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 6 publications
(7 reference statements)
0
4
0
Order By: Relevance
“…As such differences can change with time, it is recommended to measure them at least once a year (Jankowski & Sucksdorff, 1996;INTERMAGNET Technical Reference Manual, 2012). One should bear in mind that the project of the measurement pavilion was developed to accommodate photographic registration of the field's components, while the sensitive digital magnetometers we have today do require qualitatively different conditions.…”
Section: Short Notementioning
confidence: 99%
See 1 more Smart Citation
“…As such differences can change with time, it is recommended to measure them at least once a year (Jankowski & Sucksdorff, 1996;INTERMAGNET Technical Reference Manual, 2012). One should bear in mind that the project of the measurement pavilion was developed to accommodate photographic registration of the field's components, while the sensitive digital magnetometers we have today do require qualitatively different conditions.…”
Section: Short Notementioning
confidence: 99%
“…In the expression (4), the relative error ΔF st F st of the stationary scalar magnetometer was determined both by its technical characteristics (for POS-1 it can be around ≤2.5 • 10 -5 (Khomutov, 2017; Denisova et al, 2002)) and the specifics of its installation and exploitation. Due to noticeable POS-1 data noise, minimal filtering (arithmetic averaging or Gaussian filter) was applied.…”
Section: Measurement Errormentioning
confidence: 99%
“…The magnetic variations were measured using the digital quartz station "Quartz-9" based on Bobrov quartz sensors and the fluxgate variometer FRG-601, the specifications are presented, for example, in the review [12]). These magnetometers were almost fully compliant with INTERMAGNET standards.…”
Section: Processing Of Digital Magnetic Data (Standard Magnetometers)mentioning
confidence: 99%
“…The observatories KHB, MGD and PET of IKIR FEB RAS with IMO status and the observatory CPS cover the territory of the Far East from the southern border of Russia to the Arctic. Observatories are substentially equipped with the same type of magnetometers (dIdD GSM-19FD, Mag-01H, POS-1, GSM-19 and others), use standard software and perform measurements by standard methods ( [8], [12], [13]). The free exchange of results, the maintenance of a common database and the rapid exchange of information about the conditions during measurements can effectively solve the problems of magnetic monitoring and provide interchangeability in the analysis and processing of raw data.…”
Section: Observatories Of Ikir Feb Rasmentioning
confidence: 99%