2021
DOI: 10.3390/molecules26072061
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic Micro-Solid-Phase Extraction Using a Novel Carbon-Based Composite Coupled with HPLC–MS/MS for Steroid Multiclass Determination in Human Plasma

Abstract: A micron-sized sorbent, Magn-Humic, has been prepared by humic acids pyrolysis onto silica-coated magnetite. The material was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), thermogravimetric analysis (TGA), and Brunauer, Emmett, and Teller (BET) surface area measurements and applied for simultaneous magnetic solid-phase extraction (MSPE) of glucocorticoids, estrogens, progestogens, and androgens at ng mL−1 levels from human pla… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 35 publications
0
6
0
1
Order By: Relevance
“…MDLs and MQLs (ng g −1 ) were calculated from the matrix-matched calibration curves as 3.3 and 10 times the ratio between the baseline noise away from the peak tail and the regression line slope, respectively, taking into consideration the whole sample treatment [ 30 , 31 , 32 ].…”
Section: Methodsmentioning
confidence: 99%
“…MDLs and MQLs (ng g −1 ) were calculated from the matrix-matched calibration curves as 3.3 and 10 times the ratio between the baseline noise away from the peak tail and the regression line slope, respectively, taking into consideration the whole sample treatment [ 30 , 31 , 32 ].…”
Section: Methodsmentioning
confidence: 99%
“…Magn-Humic čestice pripremljene pirolizom humične kiseline na silikagel za ekstrakciju steroida iz plazme. 31 Osim što su se oba ekstrakcijska postupka pokazala iznimno jednostavnim, tim tehnikama postignute su iznimno niske LOD vrijednosti (manje od 0,8 µg l −1 ). Premda ono istiskuje nadogradnju postojeće analitičke opreme, brojne su prednosti tog načina rada, od automatizacije postupka do veće ekološke prihvatljivosti kao i manje izloženosti analitičara organskim otapalima.…”
Section: Disprezivna Mikroekstrakcija čVrstom Fazomunclassified
“…Some traditional procedures, such as liquid-liquid extraction (LLE) and solid-liquid extraction (SLE), have certainly been frequently used for regular investigations with excellent results. However, there are several drawbacks, such as the usage of massive quantities of toxic organic liquids and the amount of time it takes for the extraction methods [15]. Furthermore, in LLE, achieving restricted sample preparation parameters and the likelihood of emulsion is a critical barrier to achieving the extraction accuracy and effectiveness of the assessment.…”
Section: Introductionmentioning
confidence: 99%