1991
DOI: 10.1016/0304-8853(91)90221-u
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic measurement of interaction effects in CoNiCr and CoPtCr thin film media

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
29
0
1

Year Published

1993
1993
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 83 publications
(30 citation statements)
references
References 13 publications
0
29
0
1
Order By: Relevance
“…Such a projection is equivalent to integrating along H, leading to ‫ץ͑͐‬ 2 M͑H R , H͒ / ‫ץ‬H R ‫ץ‬H͒dH = dM͑H R ͒ / dH R , which also characterizes the switching field distribution ͑SFD͒. Conventionally, the SFD information is determined from the dc-demagnetization ͑DCD͒ remanence curve, 20,21 by taking the full width at half maximum of the dM r ͑H R ͒ / dH R curve, where M r ͑H R ͒ is the zero-field magnetization along a FORC with reversal field H R . Thus, the FORC projection and the DCD methods are similar.…”
mentioning
confidence: 99%
“…Such a projection is equivalent to integrating along H, leading to ‫ץ͑͐‬ 2 M͑H R , H͒ / ‫ץ‬H R ‫ץ‬H͒dH = dM͑H R ͒ / dH R , which also characterizes the switching field distribution ͑SFD͒. Conventionally, the SFD information is determined from the dc-demagnetization ͑DCD͒ remanence curve, 20,21 by taking the full width at half maximum of the dM r ͑H R ͒ / dH R curve, where M r ͑H R ͒ is the zero-field magnetization along a FORC with reversal field H R . Thus, the FORC projection and the DCD methods are similar.…”
mentioning
confidence: 99%
“…Computer simulations [10,11] as well as experiments [5,12] indicate a close relation between the exchange and noise in longitudinal recording media with the noise becoming larger as the interaction becomes stronger. However, since in perpendicular recording media no free charges are generated within bit transitions the recording performance will be less affected by strong exchange interactions as compared to longitudinal recording media.…”
Section: -------------------mentioning
confidence: 85%
“…Measurements of the variation of remanence with angle were made at different points along the tape using a VSM with maximum field of 10 kOe. The SFD for each sample was determined from the DCD curve measured on a PMC AGFM with a maximum field of 10 kOe by differentiation and normalization of the DCD curve [7]. The physical orientation was determined using a JEOL-1200Ex TEM.…”
Section: Methodsmentioning
confidence: 99%