Order By: Relevance
“…In recent studies on alignment uncertainties from the Brazilian Synchrotron Light Laboratory (LNLS) [32], CMM alignment measurements uncertainties of both contact and non-contact probe heads were performed using a calibrated artefact. The alignment target for the 1.8 m assemblies was quoted as a 40 µm error and not as uncertainty; no confidence interval was given.…”
Section: State Of the Artmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent studies on alignment uncertainties from the Brazilian Synchrotron Light Laboratory (LNLS) [32], CMM alignment measurements uncertainties of both contact and non-contact probe heads were performed using a calibrated artefact. The alignment target for the 1.8 m assemblies was quoted as a 40 µm error and not as uncertainty; no confidence interval was given.…”
Section: State Of the Artmentioning
confidence: 99%
“…However, the calculation or prediction of the full 'task-specific' uncertainty of each CMM was not shown. Details were missing of the specific CMM and probe head uncertainties for the different tools, thermal effects, targets form error, and others [32]. This might not be adequate when the tolerances studied are at the limit of the metrology performance.…”
Section: State Of the Artmentioning
confidence: 99%
“…In this sense, the deviations between magn etic and geometric centerlines of the magnets are assumed to be systematic or negligible. Other papers deal specifically with the magnetic axis measurement and magnet-to-magnet alignment [31,32]. Simulations of the complete alignment procedure show that an alignment envelope between girders of 0.080 mm can be attained, at a coverage probability of 95%, using laser trackers as main measuring tool.…”
Section: Subject Mattermentioning
confidence: 99%
“…Internal view of the Sirius tunnel with main dimensions. The detail shows an aerial view of the construction site as of June 2017.Reprinted from[32], Copyright 2017, with permission from Elsevier.…”
mentioning
confidence: 99%
“…In the last decades, several methods have been developed to cope with the alignment of accelerator components [4,5]. Of high importance is the alignment of focusing elements, mainly quadrupole and solenoid magnets.…”
Section: Introductionmentioning
confidence: 99%