Corrosion of Reinforcement in Concrete 2007
DOI: 10.1533/9781845692285.75
|View full text |Cite
|
Sign up to set email alerts
|

Macrocell corrosion of steel in concrete – experiments and numerical modelling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 13 publications
0
9
0
Order By: Relevance
“…The most common techniques used for R p measurements, to assess the i corr of steel in RCS, were galvanostatic [3,5,70,[146][147][148][149], potentiostatic pulses [17,136,150,151], cyclic voltammetry (conducted at very low scan rates) [151][152][153][154][155][156][157][158][159], and electrochemical impedance spectroscopy (EIS) [81,[160][161][162][163][164][165][166]. The method proposed by Stern and Geary in 1957 is based on the observation of the linearity of the polarization curve together with the corrosion potential.…”
Section: Concrete Resistivity (ρ)mentioning
confidence: 99%
“…The most common techniques used for R p measurements, to assess the i corr of steel in RCS, were galvanostatic [3,5,70,[146][147][148][149], potentiostatic pulses [17,136,150,151], cyclic voltammetry (conducted at very low scan rates) [151][152][153][154][155][156][157][158][159], and electrochemical impedance spectroscopy (EIS) [81,[160][161][162][163][164][165][166]. The method proposed by Stern and Geary in 1957 is based on the observation of the linearity of the polarization curve together with the corrosion potential.…”
Section: Concrete Resistivity (ρ)mentioning
confidence: 99%
“…Electrochemical Cell Current (ECC) versus CSE that was measured through Zero Resistance Ammeter (ZRA), Model ZM3P obtained from Corrosion Service ® (McCarter and Vennesland, 2004;Jaggi et al, 2001).…”
Section: Setup Of Electrochemical Monitoring Experimentmentioning
confidence: 99%
“…(i) Half-cell potential (HCP) measurements were measured through the experimental period versus Cu/CuSO 4 electrode (CSE), Model 8-A (Tinker & Rasor R ) using a high impedance digital multimeter, Model DT-9205A, figure 1a, according to ASTM C876-91 R99 (2005). (ii) Electrochemical cell current (ECC) measurements: in the concrete-test solution system were measured, versus the CSE, using zero resistance ammeter, (ZRA), Model ZM3P (Corrosion Service) (Jäggi et al 2001;McCarter & Vennesland 2004;Abdelaziz et al 2009;Sastri 2011). This constitutes the Daniel cell model (Broomfield 2003) of measuring reinforcing steel dissolution activity (McCarter & Vennesland 2004) in the aggressive test solution systems which shares porous partitioning with the Cu/CuSO 4 .…”
Section: 2b Setup For Corrosion Test Data Measurementsmentioning
confidence: 99%