Lung Deposition of 99mTc-Radiolabeled Albuterol Delivered through a Pressurized Metered Dose Inhaler and Spacer with Facemask or Mouthpiece in Children with Asthma

Abstract: Lung deposition achieved using the spacer with facemask was higher than previously reported, with a difference of only 4.4% of total dose measured compared to the deposition with mouthpiece. This may be due to a combination of factors including pMDI formulation, and use of an antistatic spacer with a flexible, well-fitting facemask.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
43
1
2

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(47 citation statements)
references
References 26 publications
1
43
1
2
Order By: Relevance
“…On the other hand, the filter dose of salbutamol was much lower using Vortex with a facemask present than without it. Since the dead space of this mask is relatively low, leakage of air between the mask and the face model could explain the low amount of drug recovered from the filter …”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, the filter dose of salbutamol was much lower using Vortex with a facemask present than without it. Since the dead space of this mask is relatively low, leakage of air between the mask and the face model could explain the low amount of drug recovered from the filter …”
Section: Discussionmentioning
confidence: 99%
“…The authors concluded that poor aerosol deposition was common when face mask techniques were used. Ditcham et al 13 administered radiolabeled salbutamol via a spacer or nebulizer and face mask to 8 infants and found that overall mask deposition was 0.8 -5.2% and fell to 0.6 -0.4% when children were agitated or screaming. Clay et al 14 found that changing drug concentration had little effect on aerosol size or drug mass median diameter during treatment, but that aerosol particle size remained at Ͻ 1.3 m when the optimal breathing dose range was Ͻ 5 m regardless of drug concentration.…”
Section: Discussionmentioning
confidence: 99%
“…This scoring system is a modified version of the Wood asthma scoring system, 6 is age-specific, and includes assessment of breathing frequency, S pO 2 , auscultation, retraction, and dyspnea. Scores range from mild (5-7) or moderate (8 -11) to severe (12)(13)(14)(15). In all patients, initial treatment consisted of 2 consecutive doses of 0.083% albuterol delivered by a jet nebulizer connected to a face mask using 100% oxygen.…”
Section: Case Reportsmentioning
confidence: 99%
“…26 This may have important clinical implications for patients who are receiving aerosolized artificial surfactant or who do not respond to bronchodilators using standard approaches (ie, bronchiolitis). Although these findings are interesting from a research standpoint, it is unreasonable from a cost standpoint to suggest vibrating mesh or ultrasonic nebulizers over jet nebulizers for routine delivery of drugs (ie, bronchodilators).…”
Section: Aerosol Device Selectionmentioning
confidence: 99%
“…26 In fact, a mouthpiece may provide twice as much drug as a simple aerosol face mask. 25 A slow deep inhalation followed by an occasional breathhold may also help improve aerosol delivery to the lungs.…”
Section: Interface Selectionmentioning
confidence: 99%