2017
DOI: 10.1016/j.hrtlng.2017.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Lung deposition and systemic bioavailability of different aerosol devices with and without humidification in mechanically ventilated patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
41
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 51 publications
(44 citation statements)
references
References 33 publications
2
41
0
1
Order By: Relevance
“…4 [25]. We verified our finding by studies using automatic continuous positive airway pressure (auto-CPAP) [26] and non-invasive single-limb [31,32] and invasive dual-limb [30] ventilations and still found no significance between delivering aerosol in humid or dry circuits. Furthermore, we found no significant effect of switching off or on the humidifier on the clinical status of ventilated patients [24].…”
Section: Effect Of Fill Volume and Humidity On Aerosol Deliverysupporting
confidence: 77%
See 1 more Smart Citation
“…4 [25]. We verified our finding by studies using automatic continuous positive airway pressure (auto-CPAP) [26] and non-invasive single-limb [31,32] and invasive dual-limb [30] ventilations and still found no significance between delivering aerosol in humid or dry circuits. Furthermore, we found no significant effect of switching off or on the humidifier on the clinical status of ventilated patients [24].…”
Section: Effect Of Fill Volume and Humidity On Aerosol Deliverysupporting
confidence: 77%
“…1 [13, 17], but when using a dual-limb ventilation circuit, it is better to place the aerosol generator in the inspiratory limb, as shown in Fig. 2 [24,30] for better aerosol delivery.…”
Section: Introductionmentioning
confidence: 99%
“…The choice of inhaled salbutamol dosage was in accordance with previous literature. 16,18,[24][25][26][27][28][29][30][31][32][33][34][35][36] As recommended previously in studies that used single-limb NIV, 10,30 the nebulizers were placed proximal to the subject and distal to the fixed expiratory valve, as shown in Figure 1.…”
Section: Study Protocolmentioning
confidence: 99%
“…37 The urine sample volumes were measured, and aliquots were retained for salbutamol content solid-phase extraction with an Oasis MCX 60 mg, 10 mL XL cartridge (Waters Corporation, Milford, Massachusetts) with the application of a low vacuum (Ͻ3 bars) through a VAC-ELUT 10 manifold (Varian, PaloAlto,California)extractionstation. 36 Thesalbutamolamount in each extract was determined by using high-performance liquid chromatography, described in the High-Performance Liqud Chromatography Analysis.…”
Section: Study Protocolmentioning
confidence: 99%
See 1 more Smart Citation