2022
DOI: 10.1039/d1qi01669e
|View full text |Cite
|
Sign up to set email alerts
|

Luminescent porous metal–organic gels for efficient adsorption and sensitive detection of chlortetracycline hydrochloride assisted by smartphones and a test paper-based analytical device

Abstract: Developing dual functional materials for chlortetracycline hydrochloride (CTC) adsorption and detection is of great importance for wastewater treatment and pollution monitoring. Herein, three novel (Fe-Tb) JLUE-MOGs are synthesized through the...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 75 publications
0
4
0
Order By: Relevance
“…The linear relationship obtained for the detection of glufosinate was Y = 1.14027–0.000923 X , and the limit of detection (LOD) based on 3σ/b was 28 μM (σ: standard deviation of the blank signal; b: slope of the regression line) (Figure C). Compared with the previously reported glufosinate assay in Table S4, CuO/Fe 2 O 3 presented a wider range of detection. , In addition, the colorimetric detection of CTC by nanozymes was rarely reported. , The color of the solution was obviously changed after the addition of CTC, and the absorbance at 652 nm was also obviously increased. Moreover, the CTC linear relationship was Y = 0.64184 + 0.03725 X (1–10 μM), and the LOD was 0.69 μM based on 3σ/b (Figure D,E).…”
Section: Resultsmentioning
confidence: 66%
See 2 more Smart Citations
“…The linear relationship obtained for the detection of glufosinate was Y = 1.14027–0.000923 X , and the limit of detection (LOD) based on 3σ/b was 28 μM (σ: standard deviation of the blank signal; b: slope of the regression line) (Figure C). Compared with the previously reported glufosinate assay in Table S4, CuO/Fe 2 O 3 presented a wider range of detection. , In addition, the colorimetric detection of CTC by nanozymes was rarely reported. , The color of the solution was obviously changed after the addition of CTC, and the absorbance at 652 nm was also obviously increased. Moreover, the CTC linear relationship was Y = 0.64184 + 0.03725 X (1–10 μM), and the LOD was 0.69 μM based on 3σ/b (Figure D,E).…”
Section: Resultsmentioning
confidence: 66%
“…As effective drugs for challenging microbial populations, antibiotics have been widely used for preventing and treating infections of animals and plants . Chlortetracycline hydrochloride (CTC), one of the representative antibiotics, has aroused tremendous attention because of its negative effects on human and livestock health and aquatic ecosystems. , Therefore, it is particularly important to prepare portable detection sensors for pesticide residues and antibiotics to protect the environment. Nanozyme, a term defined for a nanomaterial with natural enzyme activity, is being developed for biosensing and environmental protection.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Supramolecular metal-organic gels (MOGs) possessing hierarchical pore structures for mass transfer, high internal surface areas, and high mechanical/thermal stability and showed great potential application in the field of adsorption, separation and purification. [36][37][38][39][40] Meanwhile, according to our previous work, the metal-organic gels of giant terpyridinebased supramolecular architectures were prone to form. 41 On this basis, we expected that the gel formed from S would improve the adsorption performance for dye molecules.…”
Section: Dalton Transactions Papermentioning
confidence: 95%
“…(FeÀ Tb) metallogel (JLUE-MOG) was synthesized solvothermally, resulted in materials with hierarchical porous structures, large surface areas, and abundant active sites. [191] Using the adsorption capability of MOGs for the removal of CTC is highly effective, with mechanisms involving electrostatic or π-π electron donor-acceptor (EDA) interactions, hydrogen bonding, along with water affinity, and pore filling. Moreover, the fluorescence of JLUE-MOG exhibited quenching upon CTC adsorption, with a low detection limit of 0.079.…”
Section: In Collaboration Withmentioning
confidence: 99%