2010
DOI: 10.1002/ejic.201000779
|View full text |Cite
|
Sign up to set email alerts
|

Luminescence Resonance Energy Transfer in Heterodinuclear LnIII Complexes for Sensing Biologically Relevant Anions

Abstract: Dinuclear lanthanide(III) complexes of the macrocycles 1,4-bis[1-4,7,10-tris(carbamoylmethyl)-1,4,7,10-tetraazacyclododecane]-m-xylene (1) and 1,3-bis[1-4,7,10-tris(carbamoylmethyl)-1,4,7,10-tetraazacyclododecane]-p-xylene (2)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

3
37
0

Year Published

2011
2011
2014
2014

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 46 publications
(40 citation statements)
references
References 81 publications
3
37
0
Order By: Relevance
“…Lanthanide-based probes overcome many of the limitations associated with organic fluorophores because they offer atomic-based emissions that do not photobleach, emit line-like bands (<20 nm bandwidth), have large Stokes shifts, and exhibit long luminescence lifetimes (ms). Due to these advantages, many examples of lanthanide-based probes have been reported for the detection of biologically important cations, 1 anions, 2 neutral species, 3 proteins and peptides, 4 and DNA. 5 Many of these probes rely on the ratio of two emission peaks to determine analyte concentration, but the luminescence-decay rate of Eu(III)-containing complexes should enable the determination of analyte concentration without knowledge of probe concentration or extinction coefficient.…”
mentioning
confidence: 99%
“…Lanthanide-based probes overcome many of the limitations associated with organic fluorophores because they offer atomic-based emissions that do not photobleach, emit line-like bands (<20 nm bandwidth), have large Stokes shifts, and exhibit long luminescence lifetimes (ms). Due to these advantages, many examples of lanthanide-based probes have been reported for the detection of biologically important cations, 1 anions, 2 neutral species, 3 proteins and peptides, 4 and DNA. 5 Many of these probes rely on the ratio of two emission peaks to determine analyte concentration, but the luminescence-decay rate of Eu(III)-containing complexes should enable the determination of analyte concentration without knowledge of probe concentration or extinction coefficient.…”
mentioning
confidence: 99%
“…Another possible advantage of multilanthanide complexes is Ln-sensitized luminescence [80]. In these systems, interactions at each lanthanide can be interrogated separately for ratiometric sensing, wherein the response of the probe can be determined without determining the concentration of the probe [83]. Further, some multilanthanide complexes are known to display different properties than their monometallic analogs such as a response to or cleavage of DNA and RNA for reasons that are not well understood [48, 83, 84].…”
Section: Ligand Designmentioning
confidence: 99%
“…In these systems, interactions at each lanthanide can be interrogated separately for ratiometric sensing, wherein the response of the probe can be determined without determining the concentration of the probe [83]. Further, some multilanthanide complexes are known to display different properties than their monometallic analogs such as a response to or cleavage of DNA and RNA for reasons that are not well understood [48, 83, 84]. Yet, while the study of interactions between multilanthanide luminescent probes and DNA is still in its infancy, this class of compounds has the potential to generate useful tools for gene sensing or for therapy in the medical field.…”
Section: Ligand Designmentioning
confidence: 99%
See 2 more Smart Citations