Luminescence Intensity Ratio Thermometry with Er3+: Performance Overview

Abstract: The figures of merit of luminescence intensity ratio (LIR) thermometry for Er3+ in 40 different crystals and glasses have been calculated and compared. For calculations, the relevant data has been collected from the literature while the missing data were derived from available absorption and emission spectra. The calculated parameters include Judd–Ofelt parameters, refractive indexes, Slater integrals, spin–orbit coupling parameters, reduced matrix elements (RMEs), energy differences between emitting levels us… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 35 publications
(10 citation statements)
references
References 77 publications
0
10
0
Order By: Relevance
“…Fig. 6(b) shows that the original data for the I 540 nm /I 663 nm as a function of the temperature tting with the eqn (5). Consequently the FIR based on 5 S 2 , 5 F 4 / 5 F 5 (Ho 3+ ) shows the signicant temperature dependence and well ts the eqn (5).…”
Section: Optical Temperature-sensing Propertiesmentioning
confidence: 55%
See 1 more Smart Citation
“…Fig. 6(b) shows that the original data for the I 540 nm /I 663 nm as a function of the temperature tting with the eqn (5). Consequently the FIR based on 5 S 2 , 5 F 4 / 5 F 5 (Ho 3+ ) shows the signicant temperature dependence and well ts the eqn (5).…”
Section: Optical Temperature-sensing Propertiesmentioning
confidence: 55%
“…2 Some UC luminescent materials with doping of RE 3+ ions have been studied for temperature sensors. [3][4][5][6][7] The FIR technology based on the measurement of the temperature-dependent FIR from two excited state energy levels of activators represents an accurate temperature measuring method, because the FIR from the thermally coupled levels (TCLs) of RE ions is independent of the excitation intensity uctuations, external disturbance and spectrum losses. Thus, reasonable measurement accuracy and sensitivity could be obtained with this method.…”
Section: Introductionmentioning
confidence: 99%
“…The dipole strength of the electric dipole (ED) transition is defined as 9 where U λ are the squared reduced matrix elements (RMEs), and e = 4.803 × 10 10 esu is the elementary charge. RMEs are often considered host-independent; for this reason, many researchers have consorted to using the values tabulated by Carnall et al 23 instead of calculating them for a particular host by employing Slater integrals and spin-orbit coupling parameters 24 . The magnetic dipole (MD) transition has a dipole strength that is also host-independent.…”
Section: Previous Jo Parametrisation Studiesmentioning
confidence: 99%
“…where U λ are the squared reduced matrix elements (RMEs), and e = 4.803•10 10 esu is the elementary charge. RMEs are often considered host-independent; for this reason, many researchers have consorted to using the values tabulated by Carnall et al 23 instead of calculating them for a particular host by employing Slater integrals and spin-orbit coupling parameters 24 .…”
Section: Previous Jo Parametrisation Studiesmentioning