1993
DOI: 10.1117/12.141962
|View full text |Cite
|
Sign up to set email alerts
|

<title>Time-resolved infrared radiometry (TRIR) using a focal-plane array for characterization of hidden corrosion</title>

Abstract: A time-resolved infrared radiometry technique is developed which is applicable to detection of hidden corrosion in airframe structures and which implements an InSb focalplane array. The TRIR method can measure the loss of skin thickness due to corrosion and can also detect second layer corrosion when a sealant material is present at a lap joint. It has also been shown that the presence of corrosion product can be detected on the back surface of an aluminum plate free standing in air. Other experimental studies… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

1994
1994
2001
2001

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 3 publications
(4 reference statements)
0
1
0
Order By: Relevance
“…Slow phenomena are better investigated under step heating stimulation, while fast phenomena are better monitored with pulsed thermography. Specific advantages of this technique include the ability to determine either defect depth or material's thermal characteristics from a single test without the need for a calibration measurement made on a defect-free region of the specimen [82]. Moreover, by applying heating of low energy, the time varying temperature change on the surface of the specimen can be maintained at a high level throughout the measurement process and simultaneously the parallel nature of the detection process (excitation and monitoring) allows large areas to be studied in a single test.…”
Section: Step Heating Thermography (Sht)mentioning
confidence: 99%
“…Slow phenomena are better investigated under step heating stimulation, while fast phenomena are better monitored with pulsed thermography. Specific advantages of this technique include the ability to determine either defect depth or material's thermal characteristics from a single test without the need for a calibration measurement made on a defect-free region of the specimen [82]. Moreover, by applying heating of low energy, the time varying temperature change on the surface of the specimen can be maintained at a high level throughout the measurement process and simultaneously the parallel nature of the detection process (excitation and monitoring) allows large areas to be studied in a single test.…”
Section: Step Heating Thermography (Sht)mentioning
confidence: 99%