2000
DOI: 10.1117/12.386339
|View full text |Cite
|
Sign up to set email alerts
|

<title>Optoacoustic tomography of breast cancer with arc-array transducer</title>

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
74
0
1

Year Published

2003
2003
2021
2021

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 84 publications
(75 citation statements)
references
References 5 publications
0
74
0
1
Order By: Relevance
“…An advantage inherent in the multiscale wavelet processing is that the wavelet filter simultaneously serves as an integrator, resulting in conversion of bipolar optoacoustic pressure profiles into monopolar profiles of the absorbed optical energy. 35 Three-dimensional tomographic reconstruction was performed using a 3-D reconstruction-algorithm-based radial back projection of filtered and simultaneously integrated optoacoustic signals, 25 where the integration was achieved through a multiscale wavelet transform. 32 Such reconstruction in the 3-D case uses the complete data set and, therefore, is rigorous.…”
Section: Signal Processing and Image Reconstructionmentioning
confidence: 99%
See 1 more Smart Citation
“…An advantage inherent in the multiscale wavelet processing is that the wavelet filter simultaneously serves as an integrator, resulting in conversion of bipolar optoacoustic pressure profiles into monopolar profiles of the absorbed optical energy. 35 Three-dimensional tomographic reconstruction was performed using a 3-D reconstruction-algorithm-based radial back projection of filtered and simultaneously integrated optoacoustic signals, 25 where the integration was achieved through a multiscale wavelet transform. 32 Such reconstruction in the 3-D case uses the complete data set and, therefore, is rigorous.…”
Section: Signal Processing and Image Reconstructionmentioning
confidence: 99%
“…Kruger et al successfully developed the first 2-D imaging system and imaged a sacrificed mouse using a commercial linear ultrasound array and rotation motor to generate an optoacoustic slices. 24 As the next-generation device, using the concept of an arc-shaped array previously developed for breast imaging, 25 the same group developed a 3-D system for imaging the whole mouse body. 26 The system showed good spatial resolution and was used to image optical dye phantoms, kidneys, and major vasculature of two sacrificed mice.…”
Section: Introductionmentioning
confidence: 99%
“…5 MHz, the minimum detectable pressure (MDP) was not reported [11]. However, for some earlier versions the MDP values have been presented including measured [21] and estimated using only the thermal noise generated by the detector capacitance according to the Nyquist law [19,22].…”
mentioning
confidence: 99%
“…However, from the technical standpoint, it is better using plane transducers with a focusing acoustic lens [8]. It was shown [3,9] that signal-to-noise ratio and sensitivity increase for such system leading to an improvement of the image contrast.…”
Section: Introductionmentioning
confidence: 99%
“…The section thickness corresponds to the resolution in the direction perpendicular to the image plane and is defined by the design of the transducer array. Low resolution in that direction was the main reason of the decreased quality in the design of all transducer arrays described before [3]. This problem can be solved by using an array of focused transducers [4,5,6].…”
Section: Introductionmentioning
confidence: 99%