2001
DOI: 10.1117/12.439151
|View full text |Cite
|
Sign up to set email alerts
|

<title>Merlin microbolometer camera calibration</title>

Abstract: The Low Cost Gun Launched Seeker (LCGLS) is a component of the Navy's effort to develop effective weapons for surface fire support missions by enhancing the performance of projectiles like the Extended Range Guided Munitions (ERGM) with low-cost, uncooled infrared (IR) staring focal plane array (FPA) terminal seekers. IR target images for validating target detection algorithms were collected using a Merlin long wave (LWIR) camera from Indigo Systems. This paper characterizes thecamera in order to develop perfo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…In terms of weight limitations, sUAS (under 25 kg) have only one available radiometric temperature sensor solution: microbolometer infrared sensors (below 200 gr), which have a typical spectral response from ~7 um to ~14 um, using vanadium oxide (VOx) or amorphous silicon (A-Si) as the sensor core [ 31 , 32 , 33 ]. Figure 1 shows a microbolometer camera that is suitable for thermal remote sensing applications, as well as the spectral response of the sensor.…”
Section: Introductionmentioning
confidence: 99%
“…In terms of weight limitations, sUAS (under 25 kg) have only one available radiometric temperature sensor solution: microbolometer infrared sensors (below 200 gr), which have a typical spectral response from ~7 um to ~14 um, using vanadium oxide (VOx) or amorphous silicon (A-Si) as the sensor core [ 31 , 32 , 33 ]. Figure 1 shows a microbolometer camera that is suitable for thermal remote sensing applications, as well as the spectral response of the sensor.…”
Section: Introductionmentioning
confidence: 99%
“…The out-of-focus blackbody approach was used because it is very difficult to produce a focused, uniform surface temperature of the size necessary for this application [3,4], which, considering the wide field of view (45 o to 60 o ) and 1 m minimum focusing distance of most fire service TICs, would be at least 1 m by 1 m square. The out-of-focus blackbody approach works on the assumption that the blackbody is a Lambertian surface, i.e., its thermal radiance is constant when viewed from any angle.…”
Section: Methodsmentioning
confidence: 99%
“…A shift in the MTF curve would indicate that the performance of an imager had changed, but not necessarily the cause. The MTF can be derived from a direct measurement of the line spread function or it can be obtained by differentiation of the edge spread function (ESF) 8 . The latter method was used to obtain the MTF using a commercially available analysis code 10 , SFRMAT3.…”
Section: Mtf Proceduresmentioning
confidence: 99%