1999
DOI: 10.1117/12.341033
|View full text |Cite
|
Sign up to set email alerts
|

<title>Calibration of dispersive Raman process analyzers</title>

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2001
2001
2016
2016

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 0 publications
0
17
0
Order By: Relevance
“…A neon source was u sed for wavelength calibrati on and a calibrat ed tungst en l amp was used for int ensi ty cali bration. The laser wavel ength was checked by l ooking at the po sition of the 801 Δcm -1 Ram an lin e of cyclohexane (Tedesco and Davi s, 1999). The wavelen gth calibratio n of t he sp ectrom eter can b e affected b y changes in t emper ature (DORISS experien ced a t emperat ure drop of ~7°C duri ng the deployment).…”
Section: Instrumentationmentioning
confidence: 99%
“…A neon source was u sed for wavelength calibrati on and a calibrat ed tungst en l amp was used for int ensi ty cali bration. The laser wavel ength was checked by l ooking at the po sition of the 801 Δcm -1 Ram an lin e of cyclohexane (Tedesco and Davi s, 1999). The wavelen gth calibratio n of t he sp ectrom eter can b e affected b y changes in t emper ature (DORISS experien ced a t emperat ure drop of ~7°C duri ng the deployment).…”
Section: Instrumentationmentioning
confidence: 99%
“…This is due to tolerances in the camera mounting holes. The calibration kit supplied by Kaiser Optical includes a neon source for wavelength calibration, a tungsten source for intensity calibration, and a cyclohexane standard to verify the laser wavelength (Tedesco and Davis, 1999).…”
Section: Calibrationmentioning
confidence: 99%
“…The laser wavelength was calibrated against the 801 ∆cm -1 Raman line of cyclohexane (22). A small diamond plate was placed inside the probe head in the laser beam path, so that the 1332 ∆cm -1 diamond Raman line is superimposed on all acquired spectra.…”
Section: Methodsmentioning
confidence: 99%
“…A neon source was used for wavelength calibration and a calibrated tungsten lamp was used for intensity calibration. The laser wavelength was checked by looking at the position of the 801 ∆cm -1 Raman line of cyclohexane (Tedesco and Davis, 1999 laser inside the probe head as a reference standard . The 1332 ∆cm -1 diamond Raman line is thus superimposed on all collected spectra as a calibration check.…”
Section: Raman Scatteringmentioning
confidence: 99%