Abstract:A high performance 8 to 12 pm 72-element (Hg,Cd)Te detector array has been built for an advanced diffraction-limited serial-scanned FLIR system. The average peak detectivity for the array is 1.7 x 1011 cm Hz/W which results in a cumulative detectivity ( / Dj. avg.) of 1.4 x 1012. cm Hz /W. The cumulative detectivity controls system sensitivity. The cumulative D* for this array is over 2.3 times higher than a modular FLIR array with 180 elements and a better than average peak detectivity of 4.5 x 1010 cm Hz2 /W… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.