Lower Eyelid Tension in Young Adults Determined by a Simple Lid Tensiometer

Abstract: Our simple lid tensiometer is a viable option for measuring eyelid pressure with good repeatability.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 12 publications
0
9
0
Order By: Relevance
“…However, we have not measured these pressures. The pressures and viscoelasticity of the eyelid and cornea have been measured previously using a lid tensiometer65 and microindentation method, respectively 66. Future studies will aim to adjust the parameters of the blink to match physiological pressures.…”
Section: Discussionmentioning
confidence: 99%
“…However, we have not measured these pressures. The pressures and viscoelasticity of the eyelid and cornea have been measured previously using a lid tensiometer65 and microindentation method, respectively 66. Future studies will aim to adjust the parameters of the blink to match physiological pressures.…”
Section: Discussionmentioning
confidence: 99%
“…T he pressure exerted on the eyes by the eyelids is defined as horizontal eyelid tension [1] . Although several factors can cause eyelid malposition [2] , senile involution can significantly weaken horizontal palpebral traction and eventually decrease lower eyelid tension (LET) [3] .…”
Section: Introductionmentioning
confidence: 99%
“…The degree of laxity is considered normal if the distracted distance is less than 2 mm from the cornea; values higher than 6 mm are considered to indicate laxity. Over time, numerous studies have been conducted to evaluate the use of various devices for the assessment of LET [1,[9][10][11][12][13] . However, most of these instruments, including the clamp and latex sensor, were considered infeasible due to their highly variable displacement distances and the overestimated LET values [1,9] .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Pre-operative assessment of LET is particularly important to determine the optimal surgical technique (4). Previously, several studies have investigated the use of various devices to estimate LET (4)(5)(6)(7)(8)(9). However, most of these instruments, such as the clamp placed on the eyelid margin and latex sensor inserted into the inferior fornix, were not feasible for use (4).…”
Section: Introductionmentioning
confidence: 99%