2022
DOI: 10.1155/2022/4969410
|View full text |Cite|
|
Sign up to set email alerts
|

Low-Voltage Diagnosis of Energy Distribution Network Based on Improved Particle Swarm Optimization Algorithm

Abstract: In order to improve the research on low-voltage fault diagnosis of energy distribution network, a low-voltage multiobjective diagnosis of AC/DC energy distribution network based on ICHPSO is proposed in this paper. Firstly, the types of objective functions are listed, the objective function is transformed into a single-objective function by using the linear weighting method, and the hybrid particle swarm optimization (HPSO) diagnosis algorithm is improved, which can guide the particles to escape from the local… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 26 publications
0
2
0
Order By: Relevance
“…As there are still issues with grid instability and inertia, an improved energy storage system for PV integration can solve this issue. Revaluation of the grid structure is needed to make RES integration economically feasible in the future [78,79].…”
Section: Economic Feasibility Of Large-scale Photo Voltaic Systemsmentioning
confidence: 99%
“…As there are still issues with grid instability and inertia, an improved energy storage system for PV integration can solve this issue. Revaluation of the grid structure is needed to make RES integration economically feasible in the future [78,79].…”
Section: Economic Feasibility Of Large-scale Photo Voltaic Systemsmentioning
confidence: 99%
“…It will cause varying degrees of interference in the subsequent data analysis, resulting in inaccurate or even wrong data analysis. e data must be processed and cleaned [14,15]. To more efficiently and reliably enhance data quality and validate the beneficial impact of BPNN, this paper uses the data cleaning method based on K-nearest neighbor to clean the data collected from the 10 kV network based on distribution phenomenon and verifies the effect of data cleaning with the actual data.…”
Section: Data Cleaningmentioning
confidence: 99%
“…This article has been retracted by Hindawi, as publisher, following an investigation undertaken by the publisher [1]. This investigation has uncovered evidence of systematic manipulation of the publication and peer-review process.…”
mentioning
confidence: 99%