1989
DOI: 10.1097/00000542-198909001-00171
|View full text |Cite
|
Sign up to set email alerts
|

Low Sensitivity of the Anion Gap as a Screen to Detect Hyperlactatemia in Critically Ill Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
49
2
5

Year Published

1997
1997
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(60 citation statements)
references
References 0 publications
4
49
2
5
Order By: Relevance
“…In all studies, an increased anion gap was denoted when it exceeded the upper range of normal, either 12 or 16 mEq/L. In the first study, 43% of 56 patients with a serum lactate between 2.5 and 4.9 mmol/L and 50% of them with serum lactate between 5 and 9.9 mmol/L had a normal serum anion gap (,12 mEq/L) (25). Similarly, in 272 consecutive patients seen in the emergency department in whom serum lactate and anion gaps were obtained simultaneously, only 58% of those with a serum lactate .2.5 mmol/L had an anion gap outside the normal range (26).…”
Section: Recognition Of An Increase In the Serum Anion Gapmentioning
confidence: 99%
“…In all studies, an increased anion gap was denoted when it exceeded the upper range of normal, either 12 or 16 mEq/L. In the first study, 43% of 56 patients with a serum lactate between 2.5 and 4.9 mmol/L and 50% of them with serum lactate between 5 and 9.9 mmol/L had a normal serum anion gap (,12 mEq/L) (25). Similarly, in 272 consecutive patients seen in the emergency department in whom serum lactate and anion gaps were obtained simultaneously, only 58% of those with a serum lactate .2.5 mmol/L had an anion gap outside the normal range (26).…”
Section: Recognition Of An Increase In the Serum Anion Gapmentioning
confidence: 99%
“…[7][8][9][10][11][12][13] Penilaian kadar laktat darah pasien sakit gawat dapat digunakan sebagai salah satu indikator untuk mendeteksi secara dini keparahan dan atau derajat berat penyakit. 12,[14][15][16][17][18][19] Pada kelompok asidosis metabolik laktat, terdapat gangguan sistem organ yaitu, 1). Infeksi 22,5% terbanyak pasien dirawat dengan Sindrom dengue syok dan syok septik, 2).…”
Section: Pembahasanunclassified
“…Kadar laktat darah seringkali digunakan untuk mendeteksi hipoperfusi dan hipoksia atau sebagai parameter untuk monitor keberhasilan terapi serta prognostik pada berbagai keadaan sakit gawat. 11,12,16,17,19,20 Beberapa data laboratorium diprediksi berpengaruh pada prognosis dan mortalitas selain kadar laktat 2 , base exces, elektrolit darah dan albumin. Asidosis sangat dipengaruhi oleh konsentrasi ion hidrogen (pH), peningkatan risiko mortalitas terjadi jika pH darah <7,1 (asidosis berat) dan pH <6,8 bersifat letal.…”
Section: Pembahasanunclassified
“…1 Insensitivity: it has been found that the anion gap is relatively poor at identifying small changes in ion concentrations, especially lactate [103], even when they would be considered clinically significant.…”
Section: Limitations Of the Anion Gapmentioning
confidence: 99%