2011
DOI: 10.1063/1.3544050
|View full text |Cite
|
Sign up to set email alerts
|

Low noise and wide bandwidth of NbN hot-electron bolometer mixers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
38
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(39 citation statements)
references
References 18 publications
1
38
0
Order By: Relevance
“…A possible method to extend the GBW up to 6.5 GHz for NbN-based HEB mixers was discussed in Ref. 12, where electron diffusion from the bolometer into the contact pads was observed.…”
mentioning
confidence: 99%
“…A possible method to extend the GBW up to 6.5 GHz for NbN-based HEB mixers was discussed in Ref. 12, where electron diffusion from the bolometer into the contact pads was observed.…”
mentioning
confidence: 99%
“…2) consists of a centre piece of a thin film of a superconductor, usually niobium-nitride (NbN), although niobium-titanium-nitride (NbTiN) has been used as well (Muñoz et al, 2006). In practice (Tretyakov et al, 2011), the devices are made of a 3 to 4 nm thick film shaped to a width W and length L. The aspect ratio is determined by the desired impedance taking the normal state resistance of the superconducting film as a guideline. As illustrated in the figure, the devices consist of 2 more crucial parts.…”
Section: Brief Description Of Standard Devicesmentioning
confidence: 99%
“…2 has been developed at Moscow State University of Education (MSUE) (Shcherbatenko et al, 2016;Tretyakov et al, 2011). In general, different choices have been made at different laboratories, mostly based on trial and error, with little conceptual guidance.…”
Section: Brief Description Of Standard Devicesmentioning
confidence: 99%
“…As a consequence of that the high number (up to 17) harmonics generated by the SSL have quite little power (less than nW), a low noise and high sensitive THz receiver is necessary. We applied the NbN superconductive hot electron bolometer (HEB) operating in the direct-detection mode [4,5].The test measurements of the water and deuterium water vapor spectral absorption lines with the spectrometer were performed at 1456-1495 GHz, 1680-1725 GHz and 1904-1955 GHz frequency bands. One of the absorption line spectra is presented at Fig.…”
mentioning
confidence: 99%
“…As a consequence of that the high number (up to 17) harmonics generated by the SSL have quite little power (less than nW), a low noise and high sensitive THz receiver is necessary. We applied the NbN superconductive hot electron bolometer (HEB) operating in the direct-detection mode [4,5].…”
mentioning
confidence: 99%