Low energy stopping powers of some heavy ions in gold

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

1979
1979
2016
2016

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 9 publications
1
8
0
Order By: Relevance
“…A shows S rel for O ions in solid targets versus the specific energy E 1 =A 1 (where A 1 is the mass number of the projectile). The figure shows many points lying very close to each other, and also some apparently discrepant points: between 0.7 and 2.2 MeV, Au data (due to [12]) appear too high, while Au data by other authors in the same energy region appear reasonable [5]; the same is true for the Au data below 0.03 MeV due to [13]. These data and a few others were rejected, i.e., omitted from further consideration (see Table 2 of [14]).…”
Section: The Program Mstarsupporting
confidence: 54%
See 2 more Smart Citations
“…A shows S rel for O ions in solid targets versus the specific energy E 1 =A 1 (where A 1 is the mass number of the projectile). The figure shows many points lying very close to each other, and also some apparently discrepant points: between 0.7 and 2.2 MeV, Au data (due to [12]) appear too high, while Au data by other authors in the same energy region appear reasonable [5]; the same is true for the Au data below 0.03 MeV due to [13]. These data and a few others were rejected, i.e., omitted from further consideration (see Table 2 of [14]).…”
Section: The Program Mstarsupporting
confidence: 54%
“…N 0-0.01 Data in Ni, Cu, Ag by [31] (IDSA method) appear high since they extrapolate to a finite value at zero energy. Ne 0-0.01 Data in Au by [13] appear low (note that other data by [13] had to be rejected, see Table 2 of [14]). Ne 0.1-1 Data in C by [32] are high, while data in Ag by [33] are low compared to other data.…”
Section: Accuracy Of Other Programsmentioning
confidence: 99%
See 1 more Smart Citation
“…The dashed curves are obtained from TRIM90, TRIM92, TRIM95 [24] and HU90 [43]. The letters are the experimental data taken from Sa91 [57], Se60 [70], Wr79 [28], Ay82 [58], Ku 88 [54], Po61a [26], Ta83 [68], Ab91 [59], Ant91 [60], Ab93 [51], Pt76 [71], Tp62 [69], and Nd77 [56].…”
Section: Results and Comparison With Experimentsmentioning
confidence: 99%
“…The dashed lines are obtained from TRIM90, TRIM92, TRIM95 [24] computer code and HU90 [43]. The letters are the experimental data taken from Po61a [26], Wr79 [28], Wr72 [45], Sa92 [29], Ab93 [51], BG65 [32], Sk86 [52], Ga87 [33], Am68 [53], Bt66 [49], Bi90 [39], Ku88 [54], Sk90 [55], Sd74 [50], Bi78 [48] and Nd77 [56]. Figure 1.…”
Section: Results and Comparison With Experimentsmentioning
confidence: 99%