2022
DOI: 10.1136/rmdopen-2021-002149
|View full text |Cite
|
Sign up to set email alerts
|

Low-dose CT hounsfield units: a reliable methodology for assessing vertebral bone density in radiographic axial spondyloarthritis

Abstract: ObjectiveStudying vertebral bone loss in radiographic axial spondyloarthritis (r-axSpA) has been challenging due to ectopic bone formation. We cross-sectionally analysed low-dose CT (ldCT) trabecular bone density Hounsfield units (HU) measurements and calculated inter-reader reliability at the vertebral level in patients with r-axSpA.MethodsLdCT scans of 50 patients with r-axSpA from the sensitive imaging in ankylosing spondylitis study, a multicentre 2-year prospective cohort were included. Trabecular bone HU… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
29
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(29 citation statements)
references
References 28 publications
0
29
0
Order By: Relevance
“… 28 This methodology was shown by us, in the same patients with r-axSpA from the SIAS cohort, to be feasible and reliable from C3 to L5. 28 Lower HU values denote a lower ldCT attenuation, with less-dense bones presenting lower HU values. While avoiding the overestimation of BMD reported in DXA (ldCT HU measurements are taken from the centre of the vertebra), this methodology enabled bone density assessments in the entire spine.…”
Section: Discussionmentioning
confidence: 76%
See 4 more Smart Citations
“… 28 This methodology was shown by us, in the same patients with r-axSpA from the SIAS cohort, to be feasible and reliable from C3 to L5. 28 Lower HU values denote a lower ldCT attenuation, with less-dense bones presenting lower HU values. While avoiding the overestimation of BMD reported in DXA (ldCT HU measurements are taken from the centre of the vertebra), this methodology enabled bone density assessments in the entire spine.…”
Section: Discussionmentioning
confidence: 76%
“…A standardised protocol was applied in both centres for imaging acquisitions. 18 MRI images were acquired in Leiden and Herne, respectively, on a 3 Tesla MRI (Philips Medical systems, Best, The Netherlands) and 1.5 Tesla MRI (Siemens, Erlangen, Germany) using sagittal T1-weighted and short tau inversion recovery (STIR) sequences with a slice thickness of 3 mm. LdCT images were obtained on 64-section and 16-section CT scanners (Leiden: Aquilion 64, Toshiba Medical Systems, Otawara, Japan; Herne: Somatom Emotion 16, Siemens, Erlangen, Germany).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations