2014
DOI: 10.1016/j.electacta.2014.03.046
|View full text |Cite|
|
Sign up to set email alerts
|

Low-cost separators for enhanced power production and field application of microbial fuel cells (MFCs)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
27
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 89 publications
(33 citation statements)
references
References 33 publications
4
27
1
Order By: Relevance
“…The ohmic resistance ( R Ω ) was similar between cells in the same stack (Table ). This is due to the same materials being implemented as electrodes, membrane, connections and reactor design, which are factors that determine the R Ω . The difference observed in R Ω in the different stacks is attributed to the membrane type used, which is the only different material used between stacks of double chamber design, as was observed in a previous study, which obtained R Ω of 37 Ω y 19 Ω for two cells using the AEM AMI‐7001 and CEM Nafion® 117, respectively …”
Section: Resultsmentioning
confidence: 99%
“…The ohmic resistance ( R Ω ) was similar between cells in the same stack (Table ). This is due to the same materials being implemented as electrodes, membrane, connections and reactor design, which are factors that determine the R Ω . The difference observed in R Ω in the different stacks is attributed to the membrane type used, which is the only different material used between stacks of double chamber design, as was observed in a previous study, which obtained R Ω of 37 Ω y 19 Ω for two cells using the AEM AMI‐7001 and CEM Nafion® 117, respectively …”
Section: Resultsmentioning
confidence: 99%
“…Kondaveeti et al (2014) reported that proton mass transfer, diffusion coefficient and ion transport of the CEM were higher than them of the Nafion. Furthermore, in permselectivity test for Nafion and CEM, the Nafion was lower than the CEM (Grossi and Chao, 2014).…”
Section: Eta Degradation In a Single Air-cathode Mfcmentioning
confidence: 96%
“…Ohmic resistance was determined by noting the real axis values at a high-frequency intercept [18]. Anode and cathode potentials were measured against the Ag/AgCl (+197 vs SHE) reference electrode (Basi Inc., USA) at OCV.…”
Section: Electrochemical Analysismentioning
confidence: 99%
“…The membranes used should not allow oxygen to diffuse from the cathode to the anode compartment [18]. The oxygen mass transfer and diffusion coefficients were determined using a dissolved oxygen probe (Orion A323; Thermo Scientific Co., USA) in an uninoculated MFC.…”
Section: Oxygen Permeability Analysis and Specific Proton Conductivitymentioning
confidence: 99%
See 1 more Smart Citation