Low-concentration Oxygen Therapy Via a Demand Oxygen Delivery System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0
1

Year Published

1993
1993
2014
2014

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(21 citation statements)
references
References 4 publications
0
20
0
1
Order By: Relevance
“…For this device, oxygen flow began when negative pressure was detected and when positive pressure ceased. Tiep et al 16 invented the first prototype for contemporary PF oxygenconserving systems in 1985. This battery-operated device delivered 25 mL at the beginning of inspiration.…”
Section: Discussionmentioning
confidence: 99%
“…For this device, oxygen flow began when negative pressure was detected and when positive pressure ceased. Tiep et al 16 invented the first prototype for contemporary PF oxygenconserving systems in 1985. This battery-operated device delivered 25 mL at the beginning of inspiration.…”
Section: Discussionmentioning
confidence: 99%
“…Effective oxygen saving ratio was derived while delivering the equivalent FIO 2 to the lungs, it stand for the actual oxygen saving of DOD method compared to CFO method. It has been reported that conventional oxygen saving ratio of a DOD method had higher values up to 9.05 (Tiep and Lewis, 11 al., 19 7.55~9.05). 11,19 However, reported high oxygen saving ratios appear to be caused by the fact that equivalent FIO 2 was not considered, since conventional oxygen saving ratio was calculated as the ratio of volume of supplied oxygen by six nominal setting values in CFO to that of supplied oxygen by corresponding six setting values in DOD.…”
Section: Discussionmentioning
confidence: 99%
“…It has been reported that conventional oxygen saving ratio of a DOD method had higher values up to 9.05 (Tiep and Lewis, 11 al., 19 7.55~9.05). 11,19 However, reported high oxygen saving ratios appear to be caused by the fact that equivalent FIO 2 was not considered, since conventional oxygen saving ratio was calculated as the ratio of volume of supplied oxygen by six nominal setting values in CFO to that of supplied oxygen by corresponding six setting values in DOD. The effective oxygen saving ratio suggested in this study may provide the real index of economic oxygen saving of the DOD method while maintaining the same treatment effect compared CFO method.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Oxymatic (Chad Therapeutics) was evaluated in 12 patients with "chronic lung disease." 64 To achieve an SaO 2 measured by ear oximetry of 92% at rest required an average of 1.28 liters/min of oxygen delivered by continuous nasal flow but only 0.153 liter/min of flow using the demand delivery device. This represents an oxygen savings of 88%.…”
Section: Demand Oxygen Conserversmentioning
confidence: 99%