Abstract: Abstract. The construction and performance of dual-and triple-column systems for the analysis of dilute drug samples are described. The systems are based on the following two separation processes: (1) deproteinization and analyte fractionation using a short polymer-coated mixed-function (PCMF) phase (10 mm x 4.0 mm i.d. column) and, (2) final separation using a C18 semi-microcolumn (1.5 to 2.0 mm i.d.). The surface structure of the MF phase and the geometry of the packed column for the primary separation made … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
14
0

Year Published

1995
1995
2004
2004

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 16 publications
0
14
0
Order By: Relevance
“…Capcell Pak MF Ph-1 was an appropriate precolumn for the deproteinization and clomipramine fractionation in column-switching for microbore LC. Since MF Ph-1 phase consists of hydrophilic polyoxyethylene groups and hydrophobic phenyl groups on a silica surface [19], large molecules such as plasma proteins pass through the column quickly and clomipramine is retained longer by interacting with bonded hydrophobic groups. To choose washing solvent and the appropriate time for columnswitching, the retention behavior of clomipramine on an MF Ph-1 column was examined using different mobile phases.…”
Section: Semi-microcolumn Switching Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Capcell Pak MF Ph-1 was an appropriate precolumn for the deproteinization and clomipramine fractionation in column-switching for microbore LC. Since MF Ph-1 phase consists of hydrophilic polyoxyethylene groups and hydrophobic phenyl groups on a silica surface [19], large molecules such as plasma proteins pass through the column quickly and clomipramine is retained longer by interacting with bonded hydrophobic groups. To choose washing solvent and the appropriate time for columnswitching, the retention behavior of clomipramine on an MF Ph-1 column was examined using different mobile phases.…”
Section: Semi-microcolumn Switching Systemmentioning
confidence: 99%
“…Column-switching is a technique that directly analyses biological samples at 100/zL levels for microbore LC [16][17][18][19] as well as conventional LC [11,12,20,21]. Column-switching system based on microbore LC for clomipramine can provide higher sensitivity, shorter analysis time and easier sample treatment than other previously reported, column-switching methods for conventional LC [11,12].…”
Section: Semi-microcolumn Switching Systemmentioning
confidence: 99%
“…In this study, microbore LC was chosen for the quantitation of myristicin in serum samples because of advantages such as increased detectability and lower solvent consumption. Column-switching systems have been used for conventional LC [22][23][24][25][26] and microbore LC [27][28][29] for the online trace enrichment of analytes, which is appropriate for the isolation of myristicin from serum samples because of its volatility and low concentration.…”
Section: Chromatography and Column-switching Proceduresmentioning
confidence: 99%
“…1). Benefits of semi-microcolumn LC seemed most pronouncing when a columnswitching system was arranged [6] (Fig. 2).…”
Section: Column-switching Systemmentioning
confidence: 99%