2009
DOI: 10.1364/oe.17.009157
|View full text |Cite
|
Sign up to set email alerts
|

Low coherence interferometry for central thickness measurement of rigid and soft contact lenses

Abstract: Abstract:In this paper we propose contact lens central thickness measurement with a low coherence interferometry technique using either a SLED source or a broadband continuum generated in air-silica Microstructured Optical Fiber (MOF) pumped with a picosecond microchip laser. Each of these sources associated with the interferometer provides, at the same time, good measurement resolution and quick signal recording without moving any optical elements and without need of a Fourier Transform operation. Signal impr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
21
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(22 citation statements)
references
References 12 publications
(10 reference statements)
0
21
0
1
Order By: Relevance
“…The experimental set-up is nearly similar to the one described in reference [27]. The light of a supercontinuum source generated in an air-silica Microstructured Optical Fiber (MOF) pumped by a picoseconds microchip laser [28] is injected in a Mach-Zehnder interferometer, which is followed by a SISAM (Spectromètre Interférentiel à Sélection par l’Amplitude de Modulation) optical correlator (Fig.…”
Section: Measurement Principlementioning
confidence: 99%
See 1 more Smart Citation
“…The experimental set-up is nearly similar to the one described in reference [27]. The light of a supercontinuum source generated in an air-silica Microstructured Optical Fiber (MOF) pumped by a picoseconds microchip laser [28] is injected in a Mach-Zehnder interferometer, which is followed by a SISAM (Spectromètre Interférentiel à Sélection par l’Amplitude de Modulation) optical correlator (Fig.…”
Section: Measurement Principlementioning
confidence: 99%
“…Like other OCT, the method presented in this paper [26] is also based on low coherence interferometry and has been already applied to measurement of central thickness of contact lenses [27]. Our technique has been now adapted to be devoted to a very specific application, namely the interfaces detection of corneas after LASIK during corneal storage in Eye banks.…”
Section: Introductionmentioning
confidence: 99%
“…Contact measurement can only be utilized when machining and assembling the lenses, which has lower accuracy and even causes damage to the coated lens. The non-contact measurement methods mainly include machine vision method [9], chromatic confocal microscopy [10,11], low coherence interferometry [12], and laser differential confocal technique [13,14]. Machine vision method has advantages of continuous measurement and flexible in production line with an accuracy of less than 0.005 mm.…”
Section: Introductionmentioning
confidence: 99%
“…10,11 It uses a low-coherence TwymanGreen interferometer along with a Mach-Zehnder interferometer in transmission to measure the phase and group indices of refraction to an accuracy of 0.0001. The thickness is also required for a full description of a contact lens and has been characterized in several ways, 12,13 but it will also be determined by the interferometer described in this paper. The main purpose of the interferometer described in this paper is to provide surface measurements of a submerged contact lens in order to perform a whole lens reconstruction.…”
Section: Introductionmentioning
confidence: 99%