2018
DOI: 10.1007/s00701-018-3642-5
|View full text |Cite
|
Sign up to set email alerts
|

Loop microcatheter technique for coil embolization of paraclinoid aneurysms

Abstract: Loop microcatheter technique allowed safe and stable coil packing for paraclinoid aneurysms. The same procedural concept is also being used for aneurysms in other vascular territories.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 16 publications
(13 citation statements)
references
References 12 publications
0
12
0
1
Order By: Relevance
“…Our early first-in-human results highlight the ability of the Bendit21 to be navigated through complex vasculature without delays or vessel damage. The acute-angle branching in the internal carotid artery has presented a challenge for catheterization with conventional microcatheters 11 14 15. Likewise, the extradural (V3) curve of the vertebral artery is difficult to reproduce in microcatheters of a fixed shape 3.…”
Section: Discussionmentioning
confidence: 99%
“…Our early first-in-human results highlight the ability of the Bendit21 to be navigated through complex vasculature without delays or vessel damage. The acute-angle branching in the internal carotid artery has presented a challenge for catheterization with conventional microcatheters 11 14 15. Likewise, the extradural (V3) curve of the vertebral artery is difficult to reproduce in microcatheters of a fixed shape 3.…”
Section: Discussionmentioning
confidence: 99%
“…Stabilization of the microcatheter loop via a partially inflated balloon We already described the loop microcatheter technique for paraclinoid aneurysms. 26 However, the loop technique alone can sometimes be unstable while the coils are introduced into the aneurysm. In this situation, we additionally supported the microcatheter loop using a balloon catheter (Scepter XC™; Microvention, Tustin, CA, USA) with a double-lumen for guidewire and ballooning.…”
Section: Ballooning Strategiesmentioning
confidence: 99%
“…[3][4][5] However, a 3D-printed blood vessel model is difficult to prepare in ruptured aneurysm cases and has limited use when readjustment of the shape of the microcatheter is needed. In addition, although microcatheter shaping is reportedly decided in advance according to the location of the aneurysm, [6][7][8] the shape, angle, and length of the microcatheter should be changed according to the individual conditions depending on the direction of the aneurysm axis the microcatheter (Fig. 4D).…”
Section: Casementioning
confidence: 99%