2002
DOI: 10.1016/s0924-2031(01)00143-6
|View full text |Cite
|
Sign up to set email alerts
|

Long-wavelength near-infrared spectroscopic imaging for in-vivo skin hydration measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(21 citation statements)
references
References 8 publications
0
21
0
Order By: Relevance
“…Also in the work, Martin (1995) has experimentally obtained profiles of the measurement depth in diffuse reflectance spectroscopy. Attas et al (2002) have conducted an experiment using near infrared spectroscopic imaging with wavelength between 960nm and 1700nm for in-vivo skin hydration measurements. The system is the combination between a near infrared camera with a liquid-crystal tunable filter (LCTF) to acquire spectral images at multiple narrow wavelength bands.…”
Section: Optical Fiber Nir Spectroscopy Technique (1100-2000nm)mentioning
confidence: 99%
“…Also in the work, Martin (1995) has experimentally obtained profiles of the measurement depth in diffuse reflectance spectroscopy. Attas et al (2002) have conducted an experiment using near infrared spectroscopic imaging with wavelength between 960nm and 1700nm for in-vivo skin hydration measurements. The system is the combination between a near infrared camera with a liquid-crystal tunable filter (LCTF) to acquire spectral images at multiple narrow wavelength bands.…”
Section: Optical Fiber Nir Spectroscopy Technique (1100-2000nm)mentioning
confidence: 99%
“…Hydration Near-IR imaging has a number of useful applications in the area of dermatology including mapping tissue vasculature [27,28], highlighting inflammation [29], and gauging tissue hydration [30][31][32][33][34]. We summarize here an example to demonstrate the latter application.…”
Section: Dermatological Applications: Example Of Skinmentioning
confidence: 99%
“…Custom software was written using the LabView programming environment ͑National Instruments, Austin, TX͒ to synchronize the camera and the tunable filter ͑or filter wheel͒ and to provide an interface for images to be acquired and displayed in near-real time. The software was modified from the previous version [10][11][12][13][14] to adapt to the new computer operating system and some changes in the newer camera settings and the filter-wheel controller.…”
Section: The Nir Imaging Systemmentioning
confidence: 99%
“…[10][11][12][13][14] A rectangle area in the center of the test site was used to obtain the average pixel intensity, which is reported as the NIR score for the test site. The change-from-baseline ͑CFB͒ scores were obtained by subtracting the base line NIR score from the scores of the post-product application.…”
Section: Data and Image Analysismentioning
confidence: 99%
See 1 more Smart Citation