1980
DOI: 10.2172/5647687
|View full text |Cite
|
Sign up to set email alerts
|

Long tube heat exchanger: the facility and some preliminary tests on the down center/up annular flow configuration

Abstract: A test facility was designed and constructed to study forced flow boiling heat transfer in a cxosed loop long tube heat exchanger which is a two concentric-tube vertical design. The system consists of a 12 m long heat exchanger which can be operated at pressures to 689.3 kPa with pumped or natural convection flow rates from 0.0631 to 0.631 liters/second and which can be irradiated with a maximum steady heat flux rate of 50 kW/m2 by a set of resistive heaters operable at temperatures up to 125OOC. The facility … Show more

Help me understand this report

This publication either has no citations yet, or we are still processing them

Set email alert for when this publication receives citations?

See others like this or search for similar articles