2007
DOI: 10.1016/j.ajo.2007.03.017
|View full text |Cite
|
Sign up to set email alerts
|

Long-term Success in the Correction of Exposed Glaucoma Drainage Tubes With a Tube Extender

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 4 publications
0
10
0
Order By: Relevance
“…Improper, ragged and wide sclerostomy track for insertion of AGV tube into the AC is a major cause of concern. [2223] Leakage from tube insertion site was prevented by making an extremely small entry with the help a 22G needle. To insert the valve tube through such a tight opening was difficult.…”
Section: Discussionmentioning
confidence: 99%
“…Improper, ragged and wide sclerostomy track for insertion of AGV tube into the AC is a major cause of concern. [2223] Leakage from tube insertion site was prevented by making an extremely small entry with the help a 22G needle. To insert the valve tube through such a tight opening was difficult.…”
Section: Discussionmentioning
confidence: 99%
“… 10 , 11 Various methods of treatment of exposed tubes have been described, including debridement and placement of patch graft material, with or without repositioning the tube. 12 15 Sclera, dura, and pericardium patch graft materials were compared and found to have similar patch graft survival. 16 Prevention of tube exposure has been attempted by varying techniques, including a long scleral tunnel, different patch graft materials, 17 19 and doubling of processed pericardium allograft.…”
Section: Introductionmentioning
confidence: 99%
“…8 Other attempts at repair have involved grafting amniotic membranes over full thickness scleral grafts and using tube extenders to redirect exposed tubing through healthy conjunctiva. 9 Although these methods have proven successful in some cases, they are far from perfect. We hereby introduce 3 cases of tube exposure that were successfully managed using a new technique of burying the exposed tubing under a split-thickness hinged scleral flap.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, complete removal of the implant may be necessary. Although some studies have suggested new techniques for managing this complication, 3,8,9 a standard approach is yet to be established.…”
mentioning
confidence: 97%