2004
DOI: 10.1200/jco.2004.04.124
|View full text |Cite
|
Sign up to set email alerts
|

Long-Term Silicone Central Venous Catheters Impregnated With Minocycline and Rifampin Decrease Rates of Catheter-Related Bloodstream Infection in Cancer Patients: A Prospective Randomized Clinical Trial

Abstract: Long-term nontunneled central venous catheters impregnated with minocycline and rifampin are efficacious and safe in reducing catheter-related bloodstream infections in cancer patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
103
0
3

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 177 publications
(107 citation statements)
references
References 28 publications
1
103
0
3
Order By: Relevance
“…A study of 356 non-tunneled catheters in cancer patients showed that impregnation of central venous catheters with minocycline and rifampicin was efficacious (3 vs 14 infections in impregnated vs nonimpregnated catheters) and safe in reducing catheter-related infections. 34 Catheter-related infections may be caused by fibrin deposition associated with these catheters and interventions to decrease fibrin deposition could reduce infections. In a recent study in 208 patients 33 the use of low-dose unfractionated heparin resulted in significant less catheter-related infections (6.8 vs 16.6%).…”
Section: Discussionmentioning
confidence: 99%
“…A study of 356 non-tunneled catheters in cancer patients showed that impregnation of central venous catheters with minocycline and rifampicin was efficacious (3 vs 14 infections in impregnated vs nonimpregnated catheters) and safe in reducing catheter-related infections. 34 Catheter-related infections may be caused by fibrin deposition associated with these catheters and interventions to decrease fibrin deposition could reduce infections. In a recent study in 208 patients 33 the use of low-dose unfractionated heparin resulted in significant less catheter-related infections (6.8 vs 16.6%).…”
Section: Discussionmentioning
confidence: 99%
“…Authors were contacted for these nine studies; no more information was available for three, 11,54,60 no reply was received from four 53,61,65,72 and two authors said that they did not investigate either CRBSI or colonisation.…”
Section: Bias-funnel Plotsmentioning
confidence: 99%
“…For the 15 trials permitting more than one CVC per patient, randomisation was conducted by either randomising the CVCs to be inserted (n = 6) 11,38,57,58,64,70 or randomising patients who were due to have a CVC inserted (n = 9). Heparin CHSS CHSS, chlorhexidine and silver sulfadiazine molecularly bonded to the outer wall of the CVC body only.…”
Section: Quality Assessmentmentioning
confidence: 99%
See 1 more Smart Citation
“…In the guidelines published in 2011 was recommended the use of antimicrobial/antiseptic impregnated catheters (CHSS or rifampicin-minocycline impregnated catheters) if the CRBSI rate has not decreased after implementation of a strategy based in basic preventive measures (which include education, the use of a >0.5% chlorhexidine preparation with alcohol for skin antisepsis, and the use of maximal sterile barrier precautions) (1). This recommendation (with category IA) was based in 3 RCTs showed a reduction on the incidence of catheter tip colonisation with the use of second-generation CHSSimpregnated catheters (33)(34)(35) and two RCTs showing that rifampicin-minocycline impregnated catheters reduced the risk of CRBSI (36,37). We think that the use of antimicrobial/antiseptic impregnated catheters could reduce the incidence of CRBSI and catheter related costs.…”
mentioning