2019
DOI: 10.1016/j.ebr.2019.100345
|View full text |Cite
|
Sign up to set email alerts
|

Long-term seizure freedom following intracranial sEEG monitoring: Therapeutic benefit of a diagnostic technique

Abstract: Patients with treatment-resistant epilepsy often require surgery. It is very rare that patients with TRE can have sustained seizure freedom spontaneously, without undergoing further resection or neuro-modulation after invasive monitoring with sEEG. Of the 78 TRE cases monitored over last 5 years, we identified three patients who became seizure-free following sEEG monitoring without undergoing further resection or neuro-modulation. Seizure-freedom after sEEG is possible even without further intervention. In cas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 16 publications
(21 reference statements)
0
5
0
Order By: Relevance
“…While the literature acknowledges instances of sEEG monitoring resulting in seizure remission, these occurrences are particularly rare ( 5 ), with a previous study of epilepsy patients observing 0.5% remission rate following intracranial electrode placement. A previous case series described 3 patients with seizure remission following sEEG, however, these cases reported multiple seizures captured during the monitoring period ( 6 ), proving accurate targeting of the seizure onset zone with electrodes and suggesting the lesioning effect was not upon initial implantation but rather because of depth electrode removal or other delayed effects. In addition, none of the prior cases reported complete discontinuation of seizure medications.…”
Section: Discussionmentioning
confidence: 87%
“…While the literature acknowledges instances of sEEG monitoring resulting in seizure remission, these occurrences are particularly rare ( 5 ), with a previous study of epilepsy patients observing 0.5% remission rate following intracranial electrode placement. A previous case series described 3 patients with seizure remission following sEEG, however, these cases reported multiple seizures captured during the monitoring period ( 6 ), proving accurate targeting of the seizure onset zone with electrodes and suggesting the lesioning effect was not upon initial implantation but rather because of depth electrode removal or other delayed effects. In addition, none of the prior cases reported complete discontinuation of seizure medications.…”
Section: Discussionmentioning
confidence: 87%
“…In one series of 78 cases of treatmentresistant epilepsy, two patients remained seizure-free at 2 and 5 years of follow-up following SEEG, with a third having an initial 1-year seizure-free period followed by a return of seizures, though much milder and more infrequent. 27 Another case in 161 children with invasive monitoring, including SEEG, showed seizure freedom in two children who had depth electrodes inserted. 28 While the mechanism for these outcomes has not yet been clearly elucidated, it is reasonable to suggest that some change induced by SEEG electrode insertion has interfered, lesioned or destroyed parts of the ictal network.…”
Section: Discussionmentioning
confidence: 99%
“…This phenomenon has been reported previously. In one series of 78 cases of treatment‐resistant epilepsy, two patients remained seizure‐free at 2 and 5 years of follow‐up following SEEG, with a third having an initial 1‐year seizure‐free period followed by a return of seizures, though much milder and more infrequent 27 . Another case in 161 children with invasive monitoring, including SEEG, showed seizure freedom in two children who had depth electrodes inserted 28 .…”
Section: Discussionmentioning
confidence: 99%
“…In addition, seizure freedom following invasive monitoring with sEEG has been reported in about 0.5% of cases [ 15 , 16 ]. Often there is evidence of damage along the depth electrode tracts which could indicate unintentional lesioning of the epileptogenic network and neighboring fibers responsible for seizure spread [ 17 , 18 ]. This can also be observed without imaging evidence of a parenchymal lesion [ 19 ] as microscopic changes in neural tissue after electrode insertion could disrupt epileptogenic neurons and fibers [ 20 ].…”
Section: Discussionmentioning
confidence: 99%