2018
DOI: 10.5572/ajae.2018.12.4.326
|View full text |Cite
|
Sign up to set email alerts
|

Long-term Monitoring of Metal Elements in Total Suspended Particle Aerosols Simultaneously Collected at Three Islands in Okinawa, Japan

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 25 publications
1
3
0
Order By: Relevance
“…The elements showed in general strong variation during the investigated sampling period with a wide range of concentrations observed as revealed by their broad concentration ranges indicated by the edges of the whisker. In comparison to concentrations reported for different locations in Tunis, Tunisia (Kchih et al, 2015), the values in this study were similar for elements such as K, Cr, Cu, Mn, Ni, V, and Zn. They observed higher values for Ca (< 10 µg m −3 ), and Pb (< 2 µg m −3 ) and lower values for Fe (< 0.7 µg m −3 ), Al (< 0.6 µg m −3 ), and Ti (0.08 µg m −3 ).…”
Section: Bulk Aerosol Samplessupporting
confidence: 84%
See 1 more Smart Citation
“…The elements showed in general strong variation during the investigated sampling period with a wide range of concentrations observed as revealed by their broad concentration ranges indicated by the edges of the whisker. In comparison to concentrations reported for different locations in Tunis, Tunisia (Kchih et al, 2015), the values in this study were similar for elements such as K, Cr, Cu, Mn, Ni, V, and Zn. They observed higher values for Ca (< 10 µg m −3 ), and Pb (< 2 µg m −3 ) and lower values for Fe (< 0.7 µg m −3 ), Al (< 0.6 µg m −3 ), and Ti (0.08 µg m −3 ).…”
Section: Bulk Aerosol Samplessupporting
confidence: 84%
“…This makes the application of alternative techniques such as total reflection X-ray fluorescence spectrometry (TXRF) attractive in the analysis of particulate matter with very little mass, (typically in the microgram range) in comparison to the other techniques (Bulska and Ruszczyńska, 2017). TXRF is a highly sensitive surface technique, which is a variation in the energy-dispersive X-ray fluorescence (XRF) (Kchih et al, 2015), designed such that the X-ray beam is incident at a glancing angle on a polished substrate to enable a total internal reflection of the incident beam at its surface. This setup improves on the spectral background, increases the excitation frequency of the elements, and enhances the element sensitivity compared to conventional XRF methods (Bertin, 1975;Klockenkämper and von Bohlen, 2014a).…”
Section: Introductionmentioning
confidence: 99%
“…The northwestern monsoon prevails at this site during the cold season from late fall to early spring, implying that the air pollutants emitted from the Asian continent are easily transported here. Many researchers have reported the regional air pollution events of O 3 [29], carbon monoxide [30], black carbon [31][32][33], polycyclic aromatic hydrocarbons (PAHs) [34], PM 2.5 [35,36], metallic elements [36,37], and GEM [5,38] etc. at this site.…”
Section: Introductionmentioning
confidence: 99%
“…The method detection limit for the quartz filters was higher than 285 that observed for the polycarbonate membranes. In comparison to detection limits and blank concentrations reported from other digestion procedures using combinations of HNO3/HF for ICP-MS measurements(Upadhyay et al, 2009), and XRF(Okuda et al, 2013;Steinhoff et al, 2000;Itoh et al, 2018) analysis, the results from this method show lower detection limits for elements such as Ca, Zn, Fe, Ti, but higher limits for Sr. For Al and Co, the blank concentrations using the methods of this study were below instrument detection limit. Comparatively to 290 digestion procedures without HF, the application of HF (especially for analysis with ICP-MS technique) leads to an increase of the blank for elements such as Ca, Ti, Fe, which are partly embedded into the filter matrix and readily dissolved by HF, yielding to higher blanks for such elements as reported elsewhere(Upadhyay et al, 2009).…”
mentioning