Long-term endothelial dysfunction after coronary artery stenting

Abstract: More severe endothelial dysfunction was observed long term after stenting as compared to BA or DCA. These findings may have implications with respect to the progression of atherosclerosis in coronary arteries subjected to percutaneous interventions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
62
1
4

Year Published

2002
2002
2017
2017

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 99 publications
(70 citation statements)
references
References 15 publications
3
62
1
4
Order By: Relevance
“…13,14 Caramori et al used acetylcholine to demonstrate long-term endothelial dysfunction after BMS implantation in human coronary arteries, 14 whereas in our study, there was not a significant vasoconstrictive response at the peri-stent area with BMS. The different vasoconstrictive responses between these 2 studies may be, in part, related to the acetylcholine concentration.…”
Section: Endothelial Function After Bms Implantationcontrasting
confidence: 68%
“…13,14 Caramori et al used acetylcholine to demonstrate long-term endothelial dysfunction after BMS implantation in human coronary arteries, 14 whereas in our study, there was not a significant vasoconstrictive response at the peri-stent area with BMS. The different vasoconstrictive responses between these 2 studies may be, in part, related to the acetylcholine concentration.…”
Section: Endothelial Function After Bms Implantationcontrasting
confidence: 68%
“…Gage et al 21 and Gordon et al 25 have shown vasoconstriction of stenotic but vasodilation of normal coronary vessel segments in response to exercise. Recently, we reported that stent implantation does not impair exercise-induced coronary artery vasodilation proximal and distal to the stented vessel, 17 as it was reported by Caramori et al 26 Sabate et al 19 have reported preserved endothelium-dependent vasodilation 6 months after brachytherapy, assessed by the vasomotor response to acetylcholine infusion. The contrary findings may be related to (1) the different techniques for measuring coronary vasomotor response (ie, pharmacological assessment of endothelial function by acetylcholine infusion versus flow-mediated changes induced by bicycle exercise) and (2) the different radiation dose (our brachytherapy group received 20 Gy, the brachytherapy group studied by Sabate et al, 19 14 Gy).…”
Section: Limitationssupporting
confidence: 61%
“…Enhanced endothelial dysfunction following BMS implantation has been reported (Caramori et al, 1999;Beusekom et al, 1998). The results are slightly different between reports.…”
Section: Stentmentioning
confidence: 72%