2007
DOI: 10.1007/s10856-007-3271-7
|View full text |Cite
|
Sign up to set email alerts
|

Long-term assessment of the implant titanium material—artificial saliva interface

Abstract: This paper studies the long-term (20,000 exposure hours) behavior of titanium and Ti-5Al-4V alloy-Carter-Brugirard saliva interface and the short-term (500 exposure hours) resistance of titanium and Ti-5Al-4V alloy-Tani&Zucchi saliva interface. Potentiodynamic polarization method was applied for the determination of the main electrochemical parameters. Linear polarization measurements for to obtain the corrosion rates were used. Monitoring of the open circuit potentials (E(oc)) for long-term have permitted to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
25
0
4

Year Published

2010
2010
2019
2019

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 33 publications
(30 citation statements)
references
References 29 publications
1
25
0
4
Order By: Relevance
“…29 The fluoride ion has a slow negative influence on the electrochemical parameters due its higher corrosivity. 24,30,31 In comparison with Ti-6Al-4V alloy, from Table 4 it resulted more favorable values of all electrochemical parameters for Ti-6Al-4V-1Zr alloy, revealing the beneficial effect of Zr.…”
Section: Improvement Of Corrosion Resistance From Polarization Curvesmentioning
confidence: 91%
See 2 more Smart Citations
“…29 The fluoride ion has a slow negative influence on the electrochemical parameters due its higher corrosivity. 24,30,31 In comparison with Ti-6Al-4V alloy, from Table 4 it resulted more favorable values of all electrochemical parameters for Ti-6Al-4V-1Zr alloy, revealing the beneficial effect of Zr.…”
Section: Improvement Of Corrosion Resistance From Polarization Curvesmentioning
confidence: 91%
“…In the presence of fluoride ions, open circuit potential changed to more electronegative values due to the negative effect of F -ion; 24,30,35 the same tendency to stabilize and to ennoble was registered, showing a good, resistant passive layer.…”
Section: Improvement Of Corrosion Resistance From In Time Variations mentioning
confidence: 93%
See 1 more Smart Citation
“…A ação mecânica dos abrasivos dos dentifrícios juntamente com a ação das cerdas das escovas foi responsável pela variação da rugosidade dos espécimes, também observada por outros autores (HOSSAIN et al, 2006(HOSSAIN et al, ,2007FAIS et al,2012;SIIRILÄ E KÖNÖNEM, 1991;SALLES et al, 2009 MAYOUF et al, 2004;SARTORI et al, 2009;TONIOLLO et al, 2009;MABILLEAU et al, 2006;POPA et al, 2008;LEE, 2005) e/ou o biofilme específico (ZHANG et al, 2013;SOUZA et al, 2010).…”
Section: Grupo Beunclassified
“…A redução da proteção contra corrosão e consequente variação da rugosidade média do titânio e suas ligas foi encontrado nos estudos de Siirila e Kononen (1991), onde a concentração era de 12500 ppm; Mabilleau et al (2006), 5000 e 25000 ppm; Popa et al (2008) Na caracterização dos componentes químicos dos corpos de prova, EDS, não detectou-se a presença de sílica, tampouco compostos fluoretados ou sódicos após os testes de escovação e imersão, indicando que a reação do NaF do dentifrício e a superfície da liga de titânio não foi significativamente alterada, corroborando com os estudos expostos na literatura (NAKAGAWA et al, 1999(NAKAGAWA et al, , 2001(NAKAGAWA et al, , 2002AL-MAYOUF et al, 2004;MABILLEAU et al, 2006;MATONO et al, 2006;STAJER et al, 2008;FAIS et al, 2012;JOSKA;FOJT, 2010;MUGURUMA et al, 2011), onde a concentração de até 1500 ppm de F-não é suficiente para a degradação da superfície do titânio e suas ligas.…”
Section: Grupo Beunclassified