2013
DOI: 10.1007/s11999-013-3033-4
|View full text |Cite
|
Sign up to set email alerts
|

Long-term (20- to 25-year) Results of an Uncemented Tapered Titanium Femoral Component and Factors Affecting Survivorship

Abstract: Background Uncemented femoral components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the third decade. Questions/purposes We evaluated (1) survivorship using femoral revision for any reason as the end point; (2) survivorship using femoral revision for aseptic loosening as the end point; and (3) patient-related and surgical risk factors for aseptic stem loosening at a minimum 20-year followup with an uncemented tapered titanium stem.Methods… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
55
0
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 92 publications
(60 citation statements)
references
References 33 publications
2
55
0
1
Order By: Relevance
“…In other words, the more a stem reaches down underneath the level 80 mm below the lesser trochanter and, therefore, the more a distal movement expresses itself the less exactly the proximal stem bending can be defined. Nevertheless, stem bending ranges were within acceptable values that are comparable to the well-established CLS ® -stem (Zimmer Inc, Warsaw, IN, USA) [17,18,22]. Even though the CLS ® stem is made of a wrought Ti-6Al-7Nb alloy (Young's modulus≈ 110GPa) and therefore has elastic properties almost twice that of wrought high-nitrogen stainless steel, the cemented AMIS-K stem (X4-21Cr-9Ni-4Mn-Mo; Young's modulus≈190GPa) follows femoral bending in nearly the same way.…”
Section: Discussionsupporting
confidence: 57%
“…In other words, the more a stem reaches down underneath the level 80 mm below the lesser trochanter and, therefore, the more a distal movement expresses itself the less exactly the proximal stem bending can be defined. Nevertheless, stem bending ranges were within acceptable values that are comparable to the well-established CLS ® -stem (Zimmer Inc, Warsaw, IN, USA) [17,18,22]. Even though the CLS ® stem is made of a wrought Ti-6Al-7Nb alloy (Young's modulus≈ 110GPa) and therefore has elastic properties almost twice that of wrought high-nitrogen stainless steel, the cemented AMIS-K stem (X4-21Cr-9Ni-4Mn-Mo; Young's modulus≈190GPa) follows femoral bending in nearly the same way.…”
Section: Discussionsupporting
confidence: 57%
“…The surgical procedures were performed by multiple surgeons at one institution. The operative technique and postoperative regimen with this implant have been described [32].…”
Section: Methodsmentioning
confidence: 99%
“…However, prediction of longterm implant performance is difficult and definitive results regarding aseptic loosening are available only after lengthy followup [24,32,33]. Widespread use of poor-performing implants might occur before these results are available [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…Uncemented total hip arthroplasty in young and active patients has shown good to excellent long-term survivorship [15,16], but it still has to be considered challenging, especially with regard to longevity. MoM bearings were introduced to reduce PE wear and therefore provide long-term survival.…”
Section: Discussionmentioning
confidence: 99%