2011 International Joint Conference on Biometrics (IJCB) 2011
DOI: 10.1109/ijcb.2011.6117484
|View full text |Cite
|
Sign up to set email alerts
|

Long range iris acquisition system for stationary and mobile subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…Since longer focal lens covers a smaller view angle, methods such as pan-tilt-zoom (PTZ) and multiple cameras are proposed to expand the FoV in iris imaging [23]. Venugopalan [22] uses an off-the-shelf PTZ camera with the 360 • pan and 180 • tilt capabilities to capture unconstrained iris image between 0.5 m and 1.6 m. Even the pantilt movement with an adjustable speed up to 450 • /second, the heavy and bulky optical form factors will jeopardize the performance of response time and angular resolution when it comes to distant object. Another intuitive solution to expand the view angle of iris image capture is by increasing the number of cameras as demonstrated in the well-known IOM system from Sarnoff in 2006 [14].…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…Since longer focal lens covers a smaller view angle, methods such as pan-tilt-zoom (PTZ) and multiple cameras are proposed to expand the FoV in iris imaging [23]. Venugopalan [22] uses an off-the-shelf PTZ camera with the 360 • pan and 180 • tilt capabilities to capture unconstrained iris image between 0.5 m and 1.6 m. Even the pantilt movement with an adjustable speed up to 450 • /second, the heavy and bulky optical form factors will jeopardize the performance of response time and angular resolution when it comes to distant object. Another intuitive solution to expand the view angle of iris image capture is by increasing the number of cameras as demonstrated in the well-known IOM system from Sarnoff in 2006 [14].…”
Section: Related Workmentioning
confidence: 99%
“…Following this idea, recent advances have been able to extend the depth range on the order of 100's of centimeter. Telescope imaging was introduced to achieve larger standoff distance on the order of 1's of meter in range distance iris recognition [22]. Bulky optical and focus control components, however, implies critical application issues.…”
Section: Introductionmentioning
confidence: 99%
“…The IAAD system has a long working distance, but it has a lower speed compared to other systems. Venugopalan's system has a number of 'burst' images [20]. Till now, these systems can not be applied in practice.…”
Section: "Stand Off" Iris Imagingmentioning
confidence: 99%
“…At the same time, they require the users to be very close to the camera to extract high-resolution information. Consequently, the majority of the works in the literature that propose to use long-range (LR) iris images are focused on improving the acquisitions system using specific technologies [5,13,37,49].…”
Section: Introductionmentioning
confidence: 99%