2013
DOI: 10.1016/j.snb.2013.07.086
|View full text |Cite
|
Sign up to set email alerts
|

Long period fiber grating and high sensitivity refractive index sensor based on hollow eccentric optical fiber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
15
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 45 publications
(15 citation statements)
references
References 19 publications
0
15
0
Order By: Relevance
“…The maximum sensitivities for S-18.8, S-15.0, and S-12.5 are 4722.9 nm∕RIU (RI 1.4249-1.4319), 8353.6 nm∕RIU (RI 1.4256-1.4312), and 19212.5 nm∕RIU (RI 1.4304-1.4320), respectively. Taking into account that the OSA has a wavelength resolution of 0.01 nm, the RI sensor based on S-12.5 has an RI resolution of 5.025 × 10 −7 which, to the best of our knowledge, is significantly higher than previously reported [16][17][18][19][20]. It is noted that, in this Letter, the central wavelength of the spectral dip is determined as the 3 dB mean wavelength, which is a more reliable parameter compared to the central peak wavelength.…”
mentioning
confidence: 62%
“…The maximum sensitivities for S-18.8, S-15.0, and S-12.5 are 4722.9 nm∕RIU (RI 1.4249-1.4319), 8353.6 nm∕RIU (RI 1.4256-1.4312), and 19212.5 nm∕RIU (RI 1.4304-1.4320), respectively. Taking into account that the OSA has a wavelength resolution of 0.01 nm, the RI sensor based on S-12.5 has an RI resolution of 5.025 × 10 −7 which, to the best of our knowledge, is significantly higher than previously reported [16][17][18][19][20]. It is noted that, in this Letter, the central wavelength of the spectral dip is determined as the 3 dB mean wavelength, which is a more reliable parameter compared to the central peak wavelength.…”
mentioning
confidence: 62%
“…This is caused by the formation of resonance loss peaks through coupling between the core mode and several high-order cladding modes, which are highly sensitive to outer cladding mediums. As such, TLPFGs have been used as refractive index sensors in a variety of studies [ 26 , 27 , 28 ].…”
Section: Refractive Index Sensing Characteristicmentioning
confidence: 99%
“…As a result, the Abbe refractometer can measure the absolute RI without a reference. Fiber optic-based approaches offer advantageous remote, in-situ, and distributed measurement of surrounding RI, and a lot of research efforts employing fiber gratings and interferometers [4][5][6][7][8][9][10][11] are being developed for compact, cost-effective, and high-accuracy RI measurement. Among them based on fiber gratings, tilted fiber Bragg gratings (TFBGs) have demonstrated outstanding performance in high-sensitivity RI measurement by taking advantages of well-established FBG technology and resonant excitations of cladding modes [12].…”
Section: Introductionmentioning
confidence: 99%